ODMI-1103-A
13
EXV open angle for 1# indoor unit
Actual data/8
14
EXV open angle for 2# indoor unit
Actual data/8
15
EXV open angle for 3# indoor unit
Actual data/8
16
EXV open angle for 4# indoor unit
Actual data/8
17
P
ower supply of outdoor unit
A
D data
18
Indoor unit number
The indoor unit can communicate with outdoor unit well.
19
The last error or protection code
00 means no malfunction
20
frequency value
Actual data
21
Ambient temp. of 1# indoor unit
Actual data
22
Condenser pipe temp. of 1# indoor unit
Actual data
23
Ambient temp. of 2# indoor unit
Actual data
24
Condenser pipe temp. of 2# indoor unit
Actual data
25
Ambient temp. of 3# indoor unit
Actual data
26
Condenser pipe temp. of 3# indoor unit
Actual data
27
Ambient temp. of 4# indoor unit
Actual data
28
Condenser pipe temp. of 4# indoor unit
Actual data
29
――
Check point over
For M5OA-36HRDN1-Q model:
Display
Remark
1
No.of indoor units in good connection
Actual data
2
Outdoor unit running mode code
Off:0, Cooling:2, Heating:3, Forced cooling:4
3
A indoor unit capacity
The capacity unit is horse power.If the indoor unit is not
connected,the digital display tube will show:
“――”
4
B indoor unit capacity
5
C indoor unit capacity
6
D indoor unit capacity
7
E indoor unit capacity
8
A Indoor unit capacity demand code
9
B Indoor unit capacity demand code
10
C Indoor unit capacity demand code
11
D Indoor unit capacity demand code
12
E Indoor unit capacity demand code
13
Total indoor units amendatory capacity
demand code
14
The frequency corresponding to the total
indoor units amendatory capacity demand
15
The frequency after the frequency limit
16
The frequency sending to compressor contol
chip
17
A indoor unit evaporator outlet temp.(T
2B
A)
If the temp.is lower than -9 degree, the digital display tube will
show ¡-9¡.If the temp.is higher than 70 degree,the digital display
tube will show ¡70¡. If the indoor unit is not connected,the digital
display tube will show:
“――”
18
B indoor unit evaporator outlet temp.(T
2B
B)
19
C indoor unit evaporator outlet temp.(T
2B
C)
20
D indoor unit evaporator outlet temp.(T
2B
D)
21
E indoor unit evaporator outlet temp.(T
2B
E)
22
A indoor unit room temp.(T
1
A)
23
B indoor unit room temp.(T
1
B)
24
C indoor unit room temp.(T
1
C)
25
D indoor unit room temp.(T
1
D)
26
E indoor unit room temp.(T
1
E)
Summary of Contents for M2OC-14HRDN1
Page 6: ...ODMI 1103 A 4 Wiring Diagram 4 1 M2OC 14HRDN1 Q 4 2 M2OC 14HRDN1...
Page 7: ...ODMI 1103 A 4 3 M2OC1 18HRDN1 Q M3OC1 21HRDN1 Q 4 4 M2OC 18HRDN1 M3OC 27HRDN1...
Page 8: ...ODMI 1103 A 4 5 M3OC1 27HRDN1 Q M4OC 24HRDN1 Q 4 6 M4OC1 27HRDN1 Q M4OC 27HRDN1...
Page 9: ...ODMI 1103 A 4 7 M4OC 36HRDN1 4 8 M5OA 36HRDN1 Q...
Page 11: ...ODMI 1103 A 5 4 Refrigeration circuit drawing of inverter quintuple type...