Specifications
MCAC-HTSM-2007-11
90
Outdoor Units
Sale Model
M4OA-27HRDN1
Supply electricity type
Outdoor unit supply power
Indoor Units Combination
Single
Twin
Three
Four
Power supply
V-ph-Hz
220~240-1-50
Cooling
Capacity
Btu/h
7000
~
18000
14000
~
24000
21000
~
26000
27000
Input
W
1334-1784
1730-2200
2234-2531
2529
Rated current
A
5.8
~
7.8
7.5
~
10.7
9.7
~
12.1
11.0
Heating
Capacity
Btu/h
9000
~
18000
16000
~
25000
21000
~
27000
28000
Input
W
1356-2103
1730-2653
2459-2869
2743
Rated current
A
7.2
~
11
9.3
~
14.9
12.9
~
15.3
14.5
Max. input consumption
W
4800
Max. current
A
21
Compressor
Model
TNB220FLBM1
Type
rolling piston type rotary
Brand
MITSUBISHI ELECTRIC
Capacity
Btu/h
24328
Input
W
2200
Rated current
A
9.7
Capacitor
uF
60
Refrigerant oil
ml
MEL 56/670
Outdoor fan motor
Model
YDK53-6Z
Brand
Welling
Input
W
141.5/92
Capacitor
uF
3
Speed(Hi/Lo)
r/min
815/550
Outdoor coil
Number of rows
1
Tube pitch(a)x row pitch(b)
mm
25.4X22
Fin spacing
mm
1.5
Fin type (code)
Hydrophilic aluminum
Tube outside dia. and type
mm
Φ
9.53
internal thread pipe
Coil length x height x width
mm
620 x 813 x 248
Number of circuits
2
Outdoor air flow
m
3
/h
3500/
Outdoor noise level
dB(A)
60.5
Outdoor unit
Dimension(W x H x D)
mm
968*858*355
Packing (W x H x D)
mm
1043 x 915 x 395
Net/Gross weight
kg
80/84
Refrigerant
Type
R410A
Charged volume
g
2550
Throttle type
The electric expansion valve and capillary
Design pressure
MPa
4.2/2.5
Refrigerant pipe
(between
each
indoor
unit
and
outdoor unit)
Liquid side/ Gas side
mm
Φ
6.35/
Φ
9.53
Max. refrigerant pipe length
m
15
Max. difference in level
m
10
Connection wiring
Power wiring
mm
2
2.5 x 3 cores
Signal wiring
mm
2
1
Ambient temp
°
C
Cooling(-15~43) Heating(-7~21)
Application area
m
2
70
~
90
Summary of Contents for M2OA-18HRDN1
Page 2: ......
Page 22: ...Wall mounted Type MCAC HTSM 2007 11 20 Indoor Units l Indoor Unit MSCI 12HRIN1...
Page 27: ...MCAC HTSM 2007 11 Wall mounted Type Indoor Units 25 4 Service Space...
Page 50: ...Four way Cassette Type MCAC HTSM 2007 11 48 Indoor Units 4 Service Space unit mm...
Page 59: ...MCAC HTSM 2007 11 Four way Cassette Type Indoor Units 57 10 Accessories...
Page 65: ...MCAC HTSM 2007 11 Duct Type Indoor Units 63 4 Service Space...
Page 94: ...Service Space MCAC HTSM 2007 11 92 Outdoor Units 4 Service Space...
Page 97: ...MCAC HTSM 2007 11 Wiring Diagrams Outdoor Units 95 M4OA 27HRDN1...
Page 101: ...MCAC HTSM 2007 11 Field Wiring Outdoor Units 99 8 Field Wiring...
Page 152: ...Control device MCAC HTSM 2007 11 150 Control System...
Page 153: ...MCAC HTSM 2007 11 Control device Control System 151...
Page 155: ...MCAC HTSM 2007 11 Control device Control System 153...
Page 157: ...MCAC HTSM 2007 11 Control device Control System 155...
Page 158: ...Control device MCAC HTSM 2007 11 156 Control System...