Wall-mounted Type
MCAC-HTSM-2007-11
14
Indoor Units
2. Specifications
2.1 Corona series
Sale Model
MSCI-07HRIN1
MSCI-09HRIN1
MSCI-12HRIN1
Power supply
V-ph-Hz
220~240-1-50
220~240-1-50
220~240-1-50
Supply electricity type
Outdoor unit supply power
Cooling
Capacity
Btu/h
7000
9000
12000
Input
W
37
37
44
Rated current
A
0.17
0.17
0.2
Heating
Capacity
Btu/h
8500
11000
13000
Input
W
37
37
44
Rated current
A
0.17
0.17
0.2
Indoor fan motor
Model
RPG18H
RPG18H
RPG20D
Type
AC Motor
AC Motor
AC Motor
Brand
Welling
Welling
Welling
Input
W
36
36
38
Capacitor
uF
1.2
1.2
1.5
Speed(hi/mi/lo)
r/min
1200/1000/850
1200/1000/850
1180/1000/850
Indoor coil
a.Number of rows
2
2
2
b.Tube pitch(a)x row pitch(b)
mm
21x13.37
21x13.37
21x13.37
c.Fin spacing
mm
1.5
1.3
1.3
d.Fin type
hydrophilic aluminium
hydrophilic aluminium
hydrophilic aluminium
e.Tube outside dia.and type
mm
Ф
7
Ф
7
Ф
7
Inner-groove tube
Inner-groove tube
Inner-groove tube
f.Coil length x height x width
mm
538 x 200 x 26.74
538 x 200 x 26.74
637 x 200 x 26.74
g.Number of circuits
2
2
2
Indoor air flow (Hi/Mi/Lo)
m
3
/h
400/330/300
450/340/300
510/450/340
Indoor noise level (Hi//Mi/Lo)
dB(A)
35/32/30
37/34/31
39/37/34
Indoor unit
Dimension (W x H x D)
mm
745 x 200 x 220
745 x 200 x 220
820 x 215 x 255
Packing (W x H x D)
mm
800 x 270 x 340
800 x 270 x 340
875 x 375 x 285
Net/Gross weight
kg
8/9.5
8/9.5
9/11
Refrigerant Type
R410A
R410A
R410A
Refrigerant pipe
Liquid side/ Gas side
mm
Ф
6.35/
Ф
9.53
Ф
6.35/
Ф
9.53
Ф
6.35/
Ф
12.7
Drainage water pipe diameter
mm
Ф
17.5
Ф
17.5
Ф
17.5
Controller(standard)
R71 A/E
R71 A/E
R71 A/E
Application area
m
2
13-15
16-20
21-26
Summary of Contents for M2OA-18HRDN1
Page 2: ......
Page 22: ...Wall mounted Type MCAC HTSM 2007 11 20 Indoor Units l Indoor Unit MSCI 12HRIN1...
Page 27: ...MCAC HTSM 2007 11 Wall mounted Type Indoor Units 25 4 Service Space...
Page 50: ...Four way Cassette Type MCAC HTSM 2007 11 48 Indoor Units 4 Service Space unit mm...
Page 59: ...MCAC HTSM 2007 11 Four way Cassette Type Indoor Units 57 10 Accessories...
Page 65: ...MCAC HTSM 2007 11 Duct Type Indoor Units 63 4 Service Space...
Page 94: ...Service Space MCAC HTSM 2007 11 92 Outdoor Units 4 Service Space...
Page 97: ...MCAC HTSM 2007 11 Wiring Diagrams Outdoor Units 95 M4OA 27HRDN1...
Page 101: ...MCAC HTSM 2007 11 Field Wiring Outdoor Units 99 8 Field Wiring...
Page 152: ...Control device MCAC HTSM 2007 11 150 Control System...
Page 153: ...MCAC HTSM 2007 11 Control device Control System 151...
Page 155: ...MCAC HTSM 2007 11 Control device Control System 153...
Page 157: ...MCAC HTSM 2007 11 Control device Control System 155...
Page 158: ...Control device MCAC HTSM 2007 11 156 Control System...