1.1.7.3Anti-freezing control to indoor evaporator at cooling mode( T: evaporator temp. )
Evaporator Temp.
Compressor
T< 4
°
C
Off
T > 8
°
C
On
1.1.8
Dehumidifying mode
1.1.8.1 the indoor fan is fixed in low speed
1.1.8.2 Low room temperature protection:
When room temperature decreases to below 10
°
C, indoor fan stop, when room temperature
restores to over 12
°
C, indoor fan start.
1.1.8.3 At dehumidifying mode, the anti-freezing function of the indoor heat exchanger is the same as that
of cooling mode.
1.1.9
Heating mode
1.1.9
1Indoor Fan actions at heating mode
Indoor Fan can be set at HIGH/MID/LOW/AUTO by using a remote controller, but Anti-cold wind
function prevails.
Anti-cold wind control function at heating mode
Condition
T= Indoor exchanger temp.
Indoor fan speed
Indoor exchanger temp. up
T<34
°
C
Off
34
°
C <T<37
°
C
Breeze
37
°
C <T<44
°
C
Low speed
T> 44
°
C
Setting fan speed
Indoor
exchanger
temp.
down
T> 38
°
C
Setting fan speed
33
°
C <T<38
°
C
Low speed
24
°
C <T<33
°
C
Breeze
T<24
°
C
Off
1.1.9.2 Auto wind at heating mode
Condition
T=Indoor Temp.-Setting Temp.
Indoor fan speed
Room temp. up
T<1.5
°
C
High
1.5
°
C <T<2.5
°
C
Mid.
T>2.5
°
C
Low
Room temp. down
T<1.0
°
C
High
1.0
°
C <T<2.0
°
C
Mid.
T>2.0
°
C
Low
1.1.9.3 Indoor evaporator high-temperature protection at heating mode
Condition
T= Indoor exchanger temp.
Compressor
T<48
°
C
On
53
°
C <T<63
°
C
Decrease frequency of compressor
T>63
°
C
Off
Summary of Contents for M2OA-18HRDN1
Page 2: ......
Page 22: ...Wall mounted Type MCAC HTSM 2007 11 20 Indoor Units l Indoor Unit MSCI 12HRIN1...
Page 27: ...MCAC HTSM 2007 11 Wall mounted Type Indoor Units 25 4 Service Space...
Page 50: ...Four way Cassette Type MCAC HTSM 2007 11 48 Indoor Units 4 Service Space unit mm...
Page 59: ...MCAC HTSM 2007 11 Four way Cassette Type Indoor Units 57 10 Accessories...
Page 65: ...MCAC HTSM 2007 11 Duct Type Indoor Units 63 4 Service Space...
Page 94: ...Service Space MCAC HTSM 2007 11 92 Outdoor Units 4 Service Space...
Page 97: ...MCAC HTSM 2007 11 Wiring Diagrams Outdoor Units 95 M4OA 27HRDN1...
Page 101: ...MCAC HTSM 2007 11 Field Wiring Outdoor Units 99 8 Field Wiring...
Page 152: ...Control device MCAC HTSM 2007 11 150 Control System...
Page 153: ...MCAC HTSM 2007 11 Control device Control System 151...
Page 155: ...MCAC HTSM 2007 11 Control device Control System 153...
Page 157: ...MCAC HTSM 2007 11 Control device Control System 155...
Page 158: ...Control device MCAC HTSM 2007 11 156 Control System...