The maximum water pressure ≤ 3 bar.
The maximum water temperature ≤ 70°C according to safety device setting.
Always use materials that are compatible with the water used in the system and with the materials used in the unit.
Ensure that components installed in the field piping can withstand the water pressure and temperature.
Drain taps must be provided at all low points of the system to permit complete drainage of the circuit during maintenance.
Air vents must be provided at all high points of the system. The vents should be located at points that are easily accessible
for service. An automatic air purge is provided inside the unit. Check that this air purge valve is not tightened so that
automatic release of air in the water circuit is possible.
Before continuing installation of the unit, check the following:
The units are equipped with an expansion vessel of 8L that has a default pre-pressure of 1.5 bar. To assure proper operation
of the unit, the pre-pressure of the expansion vessel might need to be adjusted.
1) Check that the total water volume in the installation, excluding the internal water volume of the unit, is at least 40L. See 14
"Technical specifications" to find the total internal water volume of the unit.
The expansion vessel volume can follow the figure below:
2) Expansion vessel volume must fit the total water system volume.
3) To size the expansion for the heating and cooling circuit.
9.4.2 Water volume and sizing expansion vessels
NOTE
In most applications this minimum water volume will be satisfactory.
In critical processes or in rooms with a high heat load though, extra water might be required.
When circulation in each space heating loop is controlled by remotely controlled valves, it is important that this
minimum water volume is kept even if all the valves are closed.
0
5
10
15
20
25
0
50
100
150
200
250
300
350
400
Ex
pa
ns
io
n
ve
ss
el
(L
)
System water volume (L)
30
Summary of Contents for M-thermal Mono Series
Page 92: ...NOTE...
Page 93: ......
Page 94: ...16125300002440 V1 0 It Fr Es Pt Pl Tu Ro Ru De Nl Manuals inn various languages...
Page 95: ...A4 105g 100g...
Page 96: ......
Page 97: ......
Page 98: ......