46
Temperature curves for cooling mode
DIP switch S1,S2 and S4 are located on the main control hydraulic module board (see "9.3.1 main control board of hydraulic
module").
Switch off the power supply before making any changes to the DIP switch settings.
WARNING
10.2.1 Function setting
10.2 DIP switch settings overview
The automatic setting curve is the ninth curve,the ninth curve can be set as following:
State:In the setting the wired controller, if T4C2<T4C1,then exchange their value; if T1SETC1<T1SETC2, then
exchange their value.
1 2 3 4
1 2 3 4
S1
S2
ON
OFF
1 2 3 4
S4
T4
- 10
≤
T4
<
15
15
≤
T4
<
22
22
≤
T4
<
30
30
≤
T4
1- T1S
16
11
8
5
2- T1S
17
12
9
6
3- T1S
18
13
10
7
4- T1S
19
14
11
8
5- T1S
20
15
12
9
6- T1S
21
16
13
10
7- T1S
22
17
14
11
8- T1S
23
18
15
12
T4
- 10
≤
T4
<
15
15
≤
T4
<
22
22
≤
T4
<
30
30
≤
T4
1- T1S
20
18
17
16
2- T1S
21
19
18
17
3- T1S
22
20
19
17
4- T1S
23
21
19
18
5- T1S
24
21
20
18
6- T1S
24
22
20
19
7- T1S
25
22
21
19
8- T1S
25
23
21
20
T4C1
T4C2
T1SETC2
T1SETC1
T4
T1S (T1S2)
Summary of Contents for M-thermal Mono Series
Page 92: ...NOTE...
Page 93: ......
Page 94: ...16125300002440 V1 0 It Fr Es Pt Pl Tu Ro Ru De Nl Manuals inn various languages...
Page 95: ...A4 105g 100g...
Page 96: ......
Page 97: ......
Page 98: ......