4.11 H1 Troubleshooting
Digital display output
4.11.1
Description
4.11.2
Communication error between outdoor unit main control board and inverter module.
M thermal Mono stops running.
Error code is displayed on outdoor unit main PCB and user interface.
Possible causes
4.11.3
Power supply abnormal.
Interference from a source of electromagnetic radiation.
Outdoor unit main PCB or inverter driven module damaged.
Procedure
4.11.4
H1
LED on the main control board of
outdoor unit and inverter module are
light
Yes
LED is not light, the board is damaged,
or have short circuit
No
Communication wires between the
main control board of outdoor unit and
inverter module is loose
Yes
Reconnect the communication wires
No
There is a source of electromagnetic
radiation near the unit, such as
high-frequency transmitter or other high
strength radiation device
Yes
Remove the source of interference
No
Replace outdoor unit main PCB and
inverter driven module in turn