![Midea M thermal A Mono Series Service Manual Download Page 42](http://html1.mh-extra.com/html/midea/m-thermal-a-mono-series/m-thermal-a-mono-series_service-manual_1790702042.webp)
M thermal Mono
202008 41
4.4 E2 Troubleshooting
Digital display output
4.4.1
Description
4.4.2
Communication error between hydronic system and user interface.
M thermal Mono stops running.
Error code is displayed on hydronic system main PCB and user interface.
Possible causes
4.4.3
Communication wires between hydronic system and user interface not connected properly.
Communication wiring X Y E terminals misconnected.
Loosened wiring within electric control box.
Interference from high voltage wires or other sources of electromagnetic radiation.
Damaged main PCB or electric control box communication terminals block.
Midea CAC Confidential