Sensor in freezer chamber
The freezer air duct foam should be dismantled before
removing this sensor.
1) Strip the tape that secures the wiring harness.
2) Then remove the sensor.
Ambient temperature sensor
The sensor is located in the main control board
installation box and sends temperature signal to
microprocessor.As the sensor connected to the main
wire, if you need to replace, you must cut the wire
Defrost sensor in freezing chamber
The defrost sensor is located on top of the evaporator.
1
)
Disconnect the connector of defrost sensor
2
)
Cut off the band which fixes the sensor.
1
)
3
)
Separate the sensor and the evaporator.