Service Manual_2020-V3.0
27
1
)
Remove the refrigerated air duct foam sponge,
separate the duct foam, and take out the electric
damper.
7.5 Air duct components in freezing chamber and fan motor
Air duct components in freezing chamber
All accessories in the freezing chamber should be
dismantled before removing the air duct components.
Remove the support iron screw;
Lift up the door of freezer,remove the door from the slide
rail;
Take out the freezer drawer;
4
)
Remove 2 screws on the cover plate of the freezing air
duct using a cross screwdriver;
5
)
Pull out it from the bottom of freezer chamber air
duct.6
)
Pull out the connector terminal of the fan motor;
7) The reverse operation for assembly
Summary of Contents for HD-676REWN
Page 5: ...Service Manual_2020 V3 0 5 1 Significant update notes None...
Page 24: ...Service Manual_2020 V3 0 24 Light of the freezing...
Page 47: ...Service Manual_2020 V3 0 47 11 Troubleshooting Method 11 1 No cooling Air cooling Electronic...
Page 48: ...Service Manual_2020 V3 0 48...
Page 49: ...Service Manual_2020 V3 0 49 11 2 No working of compressor...
Page 50: ...Service Manual_2020 V3 0 50 11 3 Inside frosting no defrosting...
Page 51: ...Service Manual_2020 V3 0 51 11 4 Inside frosting no defrosting Maintenance guidelines...
Page 52: ...Service Manual_2020 V3 0 52 11 5 Light is not on...
Page 53: ...Service Manual_2020 V3 0 53 11 6 Fan failure 11 7 Defective defrost circuit...
Page 54: ...Service Manual_2020 V3 0 54 11 8 Noise 11 9 Air duct not operated...
Page 55: ...Service Manual_2020 V3 0 55 11 10 Ice makernot make ice Option...