Service Manual_2020-V3.0
29
4
)
pull the fan blades with big strength, until it is
separated from the shaft of fan motor; if need to
replace the fan motor, the reverse operation is for
assembly
7.6 Evaporator and Defrost system
Evaporator in freezing chamber
Evaporator in freezing chamber
1
)
Remove the air duct components in freezing
chamber.
2
)
Disconnect all connectors.
3
)
Remove the welding on inlet and outlet tubes.
Remove two screws which are used to fix the evaporator
and remove the evaporator.
Components on the evaporator
Defrost heater with defrost sensor and fuse, it can be
replaced separately.
1
)
Cut off wiring terminal
2
)
Cut off the band which fixes the sensor
3
)
Cut off the band which fixes the fuse
4
)
Separate the sensor and the evaporator
5
)
Take off the defrost heater from the supporting plate
of evaporator
Summary of Contents for HD-676REWN
Page 5: ...Service Manual_2020 V3 0 5 1 Significant update notes None...
Page 24: ...Service Manual_2020 V3 0 24 Light of the freezing...
Page 47: ...Service Manual_2020 V3 0 47 11 Troubleshooting Method 11 1 No cooling Air cooling Electronic...
Page 48: ...Service Manual_2020 V3 0 48...
Page 49: ...Service Manual_2020 V3 0 49 11 2 No working of compressor...
Page 50: ...Service Manual_2020 V3 0 50 11 3 Inside frosting no defrosting...
Page 51: ...Service Manual_2020 V3 0 51 11 4 Inside frosting no defrosting Maintenance guidelines...
Page 52: ...Service Manual_2020 V3 0 52 11 5 Light is not on...
Page 53: ...Service Manual_2020 V3 0 53 11 6 Fan failure 11 7 Defective defrost circuit...
Page 54: ...Service Manual_2020 V3 0 54 11 8 Noise 11 9 Air duct not operated...
Page 55: ...Service Manual_2020 V3 0 55 11 10 Ice makernot make ice Option...