EN-18
▲
Electric circuit
▲
Permissible connection methods
CAUTION:
•
Voltage of heating elements
230V.
•
Each connection requires the
protective ground of the mains
to be connected to the PE
terminal.
Recommended
connection
method
1
For 220-240VAC mains
single-phase connection with
operating neutral conductor.
Jumpers connecting the
terminals 1-2-3. Jumper to
the terminals 4-5 for the
operation neutral conductor.
Protective conductor on .
H05VV-F
3 G 6.0 mm
2
2
For 220-240VAC mains
two-phase connection with
operating neutral conductor.
Jumpers connecting the
terminals 1-2. Jumper to
the terminals 4-5 for the
operation neutral conductor.
Protective con-ductor on .
H05VV-F
4 G 6.0 mm
2
3
For 220-240VAC mains
three-phase connection with
operating neutral conductor.
Jumpers connecting 4-5.
Phase sequence according
to 1-2-3. Jumper to the
terminals 4-5 for the
operation neutral conductor.
Protective conductor on .
H05VV-F
5 G 2.5mm
2
L1, L2, L3 = Phase N = Neutral PE = Protective ground
▲
Connecting the hob
Insert the plug located at the end of the hob’s cable
bundle into the respective sockets on the oven switch
panel.