Gas Fired Steamer
WARNING
Do not connect the steamer to the electrical supply until after the gas connection has been made.
I
NSTALLATION
D
rain
C
onnection
The drain connection must be 1̀-1/2” (37.5 mm) IPS down, preferably with one or two elbows only, maximum length 6 feet
(1830 mm) horizontal and piped to an open gap type drain. Drain pipe should be copper. DO NOT use PVC pipe – PVC
pipe may lose its rigidity or glue may fail.
CAUTION
To avoid injury or damage to the steamer, do not connect solidly to any drain connection.
Figure 1
Figure 2
Water Quality
The water supply connected to the steam generator should meet the following guidelines:
Failure to comply with Water Quality Statement on page 4 may void the warranty.
Water supplies vary from one location to another. Other factors affecting steam generation are iron content, chlorides,
and dissolved gasses. A local water treatment specialist should be consulted before installing any steam generating
equipment.
Untreated water contains scale producing minerals which can precipitate onto the surfaces in the generator. Due to
the temperatures in the generator, the minerals can bake onto the surfaces and components. This can result in early
component failure and reduced product life.
E
lectrical
C
onnection
120 VAC-60 Hz - Single Phase
Units with this electrical rating are factory supplied with a three-wire cord and three-prong plug which fits any standard
NEMA 5-15R 125 VAC, three-prong grounded receptacle. A separate 15 amp supply is needed for each unit.