MIDI Out
Pin 2: Ground
Pin 4: In+
Pin 5: In-
MIDI Thru
Pin 2: Ground
Pin 4: In+
Pin 5: In-
MIDI In
Pin 2: Ground
Pin 4: In+
Pin 5: In-
Input / Output XLR
Pin 1: Ground
Pin 2: Hot
Pin 3: Cold
RS-232
Pin 2: Receive Data
Pin 3: Transmit Data
Pin 5: GND
Input Send / Return
Tip: Hot
Ring: Cold
Sleeve: Ground
56 Way Edac Connector
(see page 41for wiring details
)
IN
OUT
THROU
Midas Can Bus
Pin 1: +18V (100mA max)
Pin 2: Can low
Pin 3: OV Can
Pin 4: Can High
Pin 5: -18V(100mA max)
CAN
BUSS
LEGEND 3000 CONNECTORS
Terminator
Consoles can be linked using the
Midas Can Bus. Depressing the
terminator defines the end of the
chain and prevents any possible
unwanted signal being sent back
up the chain.