10
10
5
5
0
20
15
30
40
vca 2
vca 1
1 vca 2
MUTE
MUTE
SOLO
SOLO
The VCA MUTE switch acts on the
pre and post fader signals of any
input channels which are assigned to
the VCA master. The switch can be
c o n t r o l l e d f r o m s n a p s h o t
automation. If desired the MUTE
can be changed to operate as an
independent AUTO MUTE switch.
This is setup in the SYSTEM menu
on the central automation control.
The VCA SOLO switch is used to
monitor the VCA master fader by
creating a mix on the solo busses
which consists of all input channels
which are assigned to the VCA
master. If a VCA solo switch is
pressed for a short time it will latch
on or off, but if it is held on for more
than 1 second the latching is
disabled and when the switch is
released the solo will turn off.
When the console is operating in
SOLO ADD MODE input channels
have priority over VCA solos and
will temporarily override them.
The VCA MASTER FADER
controls the output level of any input
channels which are assigned to the
VCA master from +10dB to off.
VCA Master Section
18
Summary of Contents for LEGEND 3000
Page 2: ......
Page 4: ......
Page 6: ......
Page 10: ......
Page 18: ...8...
Page 43: ...Automation System Control 33...
Page 58: ...48...
Page 59: ...Frame sizes and Dimensions 49...
Page 61: ...51 Rear Panel Configuration...
Page 62: ...Midas Legend 3000 Rear Panel 32 mono channel 52...
Page 63: ...53...
Page 64: ...54...
Page 65: ...Edac Wiring Diagrams 55...
Page 67: ...Block Diagrams 57...
Page 77: ...Specification and Overview 67...
Page 81: ...MIDAS L3750 Power Supply 71...
Page 83: ...Input Crib Sheet Inputs to Input No Notes 73...
Page 84: ......