IFU-001 Rev D June 2014 

 

FDA 510(k) Cleared 

 
 
V.         STORAGE 
 
 

When your CP Relief Wand® is not in use, store it in the carrying case where it will be safe from 
accidental damage. For long term storage, remove the battery and keep in dry storage area away from 
sunlight at normal room temperature. Remove gel pads when not in regular use. 
 
            Remove battery before storing   
               
 

VI.         ROUTINE MAINTENANCE 
 

 
Wipe the electrodes with alcohol regularly. Clean the outside of the CP Relief Wand® case as needed 
with a damp cloth and mild soap. Never immerse your CP-1000 in water, alcohol or other fluids, since 
this could seriously damage the internal electronics. Avoid using cleaning fluids or solvents to remove 
stains or dirt, because such liquids may damage the plastic. Keep your Wand stored in the carrying case 
when not in use. Use only fresh batteries and replace as necessary. There are no replaceable parts 
inside the CP Relief Wand®. 
 
NOTE: Like any other stainless steel product, after extended periods of use, the stainless steel 
electrodes may tarnish due to the salts in your skin.  Stainless steel tarnish will not affect operation.  
Should this occur and you wish to restore the finish, you can use a non-abrasive light duty cleaning pad 
such as Norton BearTex® #59384 or 3M Scotch Bright® hand pad to polish the electrodes. 
 
 

VII.        INSPECTION REQUIREMENTS 
 
 

Your CP Relief Wand® should provide years of dependable service. Inspect your unit regularly for 
damage. Verify that the switches and Intensity control work properly and that the indicator lamp is visible 
when turned on. Replace battery as needed.    
 

 
VIII.       MALFUNCTIONS 
 

Should any malfunctions occur while using the CP Relief Wand®, check the switches and controls for 
correct settings. 
 
If stimulation output is diminished, insert a new battery. Should there be any other problem, please return 
the unit to your dealer or factory. Do not try to repair a defective device. There are no serviceable parts in 
the CP-1000. The factory warranty will be voided if there is evidence of disassembly.  

 
 
 
 
 
 
 
IX.         WARRANTY INFORMATION 

 

Summary of Contents for CP Relief WandCP 1000

Page 1: ...D June 2014 FDA 510 k Cleared CP Relief Wand Model CP 1000 Rx Only Mid America Medical Innovations LLC 2704 Industrial Drive Jefferson City MO 65109 USA 573 556 5569 844 226 1013 RoHS Compliant Opera...

Page 2: ...se Contraindications Precautions Cautions Warnings Adverse Reactions III Operation CP Relief Wand Components CP Relief Wand Controls CP Relief Wand Battery Information CP Relief Wand Electrodes Skin P...

Page 3: ...times almost everyone traveled long distances by foot and painful feet would have been a common problem Recovered ancient artifacts show that the Egyptians and Greeks knew of the pain reducing effects...

Page 4: ...atients 6 The long term effects of electrical stimulation are unknown 7 Since the effects of stimulation of the brain are unknown the unit s electrodes should not be applied anywhere on the head 8 The...

Page 5: ...on when the patient is in the bath or shower 7 Do not apply stimulation while the patient is sleeping or while the patient is driving operating machinery or during any activity in which electrical sti...

Page 6: ...th Switch The Pulse Width Switch selects either 150 microsecond pulse width low or 230 microsecond uS pulse width high Choose the 150 microsecond uS setting for lowest power and maximum comfort during...

Page 7: ...pads dry out you can moisten them with water for continued use After repeated usage the gel pads deliver less stimulation and should be replaced as needed Always use CP Relief Wand 2088 Gel Pads Skin...

Page 8: ...an be rotated to a different angular position or the Wand can be moved to a different position Continue holding the CP Relief Wand in this position until some further reduction in pain is detected and...

Page 9: ...Like any other stainless steel product after extended periods of use the stainless steel electrodes may tarnish due to the salts in your skin Stainless steel tarnish will not affect operation Should t...

Page 10: ...age resulting from failure to follow the operating instructions accidents abuse alteration or disassembly by unauthorized personnel When returning to the factory a Return Authorization Number must be...

Page 11: ...re its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF Emissions CISPR 11 Class B The CP Relief Wand is suitable for use in all establishments...

Page 12: ...ble and mobile RF Communications equipment should be used no closer to any part of the device including cables than the recommended distance calculated from the equation applicable to the frequency of...

Page 13: ...ces are controlled The customer or user of the device can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitte...

Page 14: ...2014 FDA 510 k Cleared XI GLOSSARY Rx Sold by Prescription Only Caution Type BF Applied Part Manufactured by Mid America Medical Innovations LLC 2704 Industrial Dr Jefferson City MO 65109 USA uS Hz H...

Reviews: