TECHNICAL SPECIFICATION
3.1
Technical data
HP 1100 COMPACT
PREMIUM
HP 1500 COMPACT
PREMIUM
Air temperature/water temperature
25°C/10°C
25°C/20°C
25°C/10°C
25°C/20°C
Heating output (kW)
10.06
9.55
13.01
12.28
Power consumption (kW)
1.49
1.51
1.92
1.95
Coefficient of Performance (C.O.P.)
6,7
6.3
6.7
6.3
Recommended swimming pool volume (m
3
) (with
a cover/without a cover)
40/30
60/40
Energy class
A
A
Operating temperature – air (°C)
-5 (-15)**... +40
-5 (-15)**... +40
Optional swimming pool water temperature range (°C)
+5...+40
+5...+40
Air flow (m
3
/h)
2520
2520
Recommended water flow (m
3
/h)/pressure loss (kPa)
4-6/1-5
4-6/1-5
Feeding voltage/Protection (V/A)
230 / 20A/C
230/ 20A/C
Current-carrying capacity/max. current (A)
7/9
9/10
Coverage/Protection
IP X4/by grounding
IP X4/by grounding
Heat exchanger
Titanium
Titanium
Acoustic pressure level dB (A) 1m/2m/4m/8m
54/48/42/36
55/49/43/37
Water circuit connection (mm/inch, thread)
50/ 6/4“ internal
50/ 6/4“ internal
Max. recommended water pipe length (m)
30
30
Max. operational water pressure
0.15MPa (1.5bar)
0.15MPa (1.5bar)
Net unit dimensions (w/h/d)
870/950/320
870/950/320
Gross unit dimensions (w/h/d)
1020/1080/450
1020/1080/450
Net/Gross weight (kg)
67/73
69/75
Refrigerant/filling weight (type/kg)
R410A/1,25
R410A/1,60
* The manufacturer reserves the right to change the parameters without notice.
** In the case Winter module, condensate tray antifreeze or heat exchanger frost protection is installed.
The refrigerant circuit is filled with R410A refrigerant that consists of 2 components (R32/R125).
These components are considered as fluorocarbon greenhouse gases. The product contains
fluorocarbon greenhouse gases listed in the Kyoto Protocol:
R410A with the global warning potential (GWP) 1720 (R-32/125 50/50) CH2F2 + CF3CHF2.
3.2
Swimming pool water parameters
The heat pump is designed for heating the swimming pool water. Although the water heat exchanger
is made from the most durable titanium, in order to ensure long term reliability of the heat pump the
pool water must be in accordance with the related sanitary requirements.
The limit values for the heat pump operation are the following:
-
pH value ranging from 6.8 to 7.9,
-
total chlorine amount not exceeding 3 mg/l,
-
salt content 6% wt/wt.
Should you have different values of pH, chlorine or salt please try to apply appropriate agents or
contact your swimming pool builder to resolve the situation. Above mentioned values are
recommended for pools in general.