I n s t a l l a t i o n a n d u s e r m a n u a l
HP1100/1500 COMPACT PREMIUM
V e r s i o n : 0 1 / 2 0 1 8
P a g e 1 8 / 2 8
H
E
A
T
P
U
M
P
MI
C
R
O
W
E
L
L H
P
circulation pump off. In the case the water temperature will not trigger the heat pump in following
60 minutes, the heat pump will automatically turnt the circulation pump on for a 1 minute time in
order to recirculate water from to the pool into the heat exchanger in order to read the actual
current water temperature.
2.
Continous mode
In continuous mode will the heat pump have the circulation pump turned on and running all the
time the heat pump is in operational mode (please
refer to section 5.2 General heat pump control
for explanation of operational mode).
Continous mode achieves better water temperature readings but means higher energy
consumption of the system as the circulation pump is always on.
Continous mode can be set in manufacturing settings number 07, figure 1. (please refer
to section
5.7 Setting of the operating parameters)
3.
micro Mode
micro mode provides optimum water temperature conditioning at lowest cost. Heat
pump will have the circulation pump running only in time when the heat pump needs to heat or
cool the water. Once the requested water temperature is achieved the heat pump goes into sleep
for 30 minutes. After these 30 minutes are passed, the heat pump will have the circulation pump
running for about a minute to receive actual accurate water temperature. Should heating or
cooling be required, the heat pumps starts. Should no action be required, the heat pump goes
into 30 minute sleep again. This 30 minute period can be cancelled by pressing any button on the
controller.
micro mode can be set in manufacturing settings number 07, figure 2. (please refer
to
section 5.7 Setting of the operating parameters)
Please note that all heat pump models may not be equipped with micro mode.
4.7
Separate water circuit
In order to save energy it is possible to install the heat pump on a separate water circuit with small
circulation pump. This is appropriate in the case the power consumption of circulation pump for
filtration is considered high or simply if the whole filtration circuit running is not desired when heating
/ cooling is required.
Normally swimming pool circulation pumps with water flow performance between 4-6m
3
/h consume
up to 0.5kW of energy.
Such installation must be discussed with your swimming pool supplier, distributor or reseller.
4.8
Circulation pump connection
Manufacturer suggests connection of circulation pump through switching relay. Please refer to below
drawing for more information. Direct connection of the circulation pump is not advised.
HEAT PUMP
Circulation pump
connection
Switching phase 230VAC
Relay 230VAC
Circulation pump power supply
Circulation
pump