Automatic turning off
You can use this function when you would like your heat pump turned off after some time period. You
set the ‘Timer on’ function in operating mode (heat pump on) by pressing the ‘Clock’ button .
By pressing the buttons, you can set the number of hours after which the heat pump will
automatically turn itself off. The time setting range is 1-24 hours.
To confirm the settings, please no action for few seconds. You will see preset desired number of
hours, clock icon and icon ‘OFF’ as shown on above picture.
To cancel the timer, press the clock button again and you leave timer settings mode.
5.5
Child lock
Your heat pump controller allows you to lock its settings in order to protect them from undesired
changes. This is mainly used in the case of a risk that children would unintentionally change the
settings of the heat pump.
By pressing and holding both buttons for 5 seconds at the same time, the child lock gets
activated. In order to disactivate the child lock, please repress and hold the buttons again for 5
seconds.
5.6
Parameters check
During heat pump operations (heating or cooling) you can read several basic technical parameters.
This is mainly useful for a service technician.
Following parameters can be checked:
14 – Input water temperature (T2)
(-9°C + 99°C)
15 – Ambient air temperature (T3)
(-9°C + 99°C)
16 – Temperature on the compressor discharge (T4)
(0°C + 159°C / values above 100°C showed
as Axx, e.g. 105°C showed as ‘A05’)
17 – Evaporator temperature (T1)
(-9°C + 99°C)
18 – Output water temperature (T5)
(-9°C + 99°C)
In order to enter the Parameters check reading please press and hold the clock button for 3
seconds during the heat pump’s operational mode. The parameters will be displayed starting with
Picture: Parameters check, input
water temperature 30°C.
Picture: Child lock activated. A lock icon is