HP1100/1500COMPACT PREMIUM
I n s t a l l a t i o n a n d u s e r m a n u a l
P a g e
3 1
/ 2 8
V e r s i o n : 0 1 / 2 0 1 8
H
E
A
T
P
U
M
P
MI
C
R
O
W
E
L
L H
P
on refrigerant circuit (leakage,
restriction, not enough refrigerant, etc.)
If this error occurrs repeteadly, please
contact your distributor or reseller.
Other
Other
Please call for service.
8.
MAINTANANCE & WARRANTY
8.1
Maintanance
WARNING: The device operates at dangerous electrical current and
voltage.
DANGER: Danger of electric shock!
WARNING: The device is pressurized with refrigerant R410A. The pressures
can reach as high as 30bar.
a)
Clean the swimming pool and the filtration on regular basis to prevent the device from
damage caused by dirty or clocked filter.
b)
Check the power supply on regular basis.
c)
Should the device appear to operate in unusual way, turn it off immediately and contact your
distributor or seller.
d)
Check the working area of the pump on regular basis (see the picture in
chapter 4.1
Positioning). Keep this area clean and remove all the accumulated dirt, leaves, snow, trees or
anything that can increase the risk of air circulation blockage.
e)
If you decide not to use the heat pump, disconnect it from the mains, remove the water from
the heat exchanger (please refer
to section 7.3 Winterizing). It is advised then to cover the
unit with a water resistant sheet or with a PE foil.
f)
For external washing of the heat pump, use your common cleaning agent for dishes and pure
water.
g)
Clean the external surface of the evaporator with a soft brush on regular basis to remove
impurities. This is particularly important during bloom months. Please note that every single
barrier of free air flow reduces the efficiency of the heat pump and may lead to heat pump’s
malfunction, damage or failure.
h)
Check the evaporator surface and make sure that the lamellas are not compressed. It is
possible to flatten out the lamellas by a flat, non–edgy tool. Please be advised that the
evaporator fins are easy to compress mechanically. The warranty does not cover any
mechanical damage caused on the lamellas.
i)
Regularly check the screws, fixing the device to the base, screws fixing the covers.
j)
Depending on agressivity of exterior environment (acid rain, chemical industry in vicinity, high
UV, sea or ocean in vicinity, etc.) it is possible for a rust to appear on metal parts. It is
suggested to threat this rust in order to avoid its spread.
k)
Do not clean inner parts of water heat exchanger with hot water. The heat exchanger will get
damaged if water temperature inside it rises above 45°C.
l)
All the above measures must be performed by a trained technician.
m)
The maintenance of the refrigeration or electrical system must be performed by authorized
technicians only.