Chapter 20 Document history
Rev.
Date
Changes
05
(1/4)
13.11.2020
(1/4)
Hardware version 4.0
The sensor supply at VOUT can now be varied in the range 5...24V. Up until now
only 15V or 23.3V could be selected.
The RS485 interface is now parallel to universal inputs 3 and 4 on the main terminal
block. The 4-pin JST connector used up until now has been removed. This makes it
easier to connect devices and sensors to the RS485 interface. However, the
RS485 interface and universal inputs 3 and 4 can no longer be used at the same
time.
The 3,3V sensor supplies connected to the 7-pin JST connector of the RS232
interface (VEXT
RS232
) and the main terminal strip (VEXT) can now be switched
independently of each other.
The device now has a Bluetooth Low Energy module (reserved for extensions).
Chapter "Declaration of conformity" on page 13
Declaration of Conformity updated
Chapter "Technical data" on page 15
Specification of the housing/cover material changed to "ABS/PC"
Notices added about the fact that the RS485 interface and universal inputs 3 and 4
can no longer be used at the same time.
Number of the switchable 3,3V supply changed from 1 to 2 (VEXT and
VEXT
RS232
)
Explanation changed to the fact that the switchable and adjustable sensor supply
can be varied in range 5...24V.
Information about the Bluetooth Low Energy module added
The rapidM2M Toolset has been replaced by the web-based development
environment rapidM2M Studio .
B4 and B6 removed from the list of supported UMTS frequency bands
Order numbers added, which when specified, lead to the corresponding features
being enabled before delivery by the manufacturer.
Chapter "Overview" on page 22
Figures changed to account for the fact that the 4-pin JST connector that was used
up to now for the RS485 interface has been removed.
Chapter "Block diagram" on page 23
Pin assignment of the RS232 connector corrected
The RS485 interface is now parallel to universal inputs 3 and 4 on the main terminal
block.
The sensor supply at VOUT can now be varied in the range 5...24V.
The 3,3V sensor supplies attached to the RS232 interface (VEXT
RS232
) and the
main terminal block (VEXT) can now be switched separately to each other.
Chapter "General product information" on page 24
Notices added about the fact that the RS485 interface and universal inputs 3 and 4
can no longer be used at the same time.
Number of the switchable 3,3V supply changed from 1 to 2 (VEXT and
VEXT
RS232
)
The rapidM2M Toolset has been replaced by the web-based development
environment rapidM2M Studio .
Order numbers added, which when specified, lead to the corresponding features
being enabled before delivery by the manufacturer.
Rev. 05
271
Summary of Contents for myDatalogEASY V3
Page 2: ......
Page 13: ...Chapter 2 Declaration of conformity Chapter 2 Declaration of conformity Rev 05 13 ...
Page 14: ......
Page 42: ......
Page 76: ......
Page 88: ......
Page 102: ......
Page 110: ......
Page 116: ......
Page 234: ......
Page 244: ......
Page 252: ......
Page 254: ......
Page 266: ......
Page 276: ......