Installation of optional equipment
8.1.
MMS Minimum – quantity – lubricant unit
X
S
O
A
B
C
N
M
J
1. Screw the lubricant unit to the rear side of the machine head with two hexagon
sockets (X) (M4 x 8).
2. Plug in the electrical connection (O) at the rear side of the machine head.
3. Connect the air hose (S) to a RFL-unit and adjust the pressure to min. 4 bar,
max. 8 bar.
4. Bleed all air from the MMS and adjusting block
-
Open the lubricant tank (N) and fill it with required lubricant.
-
Open the quantity regulator of the micro pump (C), approx. 2 turns
(more lubrificant = turn right!). Start spray pulses by manual operation (srew
driver) using the valve (rear side of MMS) just until lubricant comes out.
-
Reduce quantity regulation (C) in accordance with required quantity.
-
Adjust nozzle (A) so that the lubricant cone impacts to a sheet of paper or a
cloth.
-
Adjust quantity of air using the air spray regulator (B)
-
Set quantity and air as required.
5. Programme lubricant parameters - type : spray. Choose pulse time and
frequency.
6. Adjust the nozzle (A) so that the lubricant is directed towards the hole to be
tapped.
7. Make sure that the manual operation (M) valve is switched off, that means that
the valve (J) is closed.