migra MPB PB
Large Format, Graphics Compatible Display with Profibus Interface
Page 44
microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach
+49 9681 91960-0,
+49 9681 91960-10, [email protected], www.microsyst.de
4.1 Interface Configuration / LEDs
The display unit is delivered with the following default settings:
* Baud rate:
19200 baud
* Data bits:
8
* Parity:
even
* Stop bits:
1.
For setting the serial interfaces the PC software MKS is mandatory.
LED
Function / Description
LED 1 (green) Power-up:
Blinks at a frequency of approx. 2,5 Hz
Normal operation:
Blinks at a frequency of approx. 5 Hz
Boot mode:
Blinks at a frequency of approx. 0,5 Hz
Software upload:
Flickers during the upload
Configuration:
Defective MKS:
Blinks with an Error Code: 1x
Defective Micon:
Blinks with an Error Code: 2x
LED 3 (blue)
Video-signal:
On
No Video-signal:
Off