3.6.3.5 Scrolling the Display Content
3.6.3.5.1 Displays with vertical Resolution < 64 Pixels
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6 Byte 7 Byte 8 Byte 9
ESC
Function
Direction
Speed
Increment
Start
line
tens
Start
line
ones
End
line
tens
End
line
ones
1B
h
“S“
“0”: off
“1”: up
“2”: down
“0”: static
“1”: 1.8 sec
“9”: 0.2 sec
“1”: 1 pixel
“9”: 9 pixels
“0”: no
scrolling
“0” - “9”
“0” - “9” “0” - “9”
“0” - “9”
This command scrolls once a screen area from the start line to the end line (speed
= “static”) or cyclically in steps of 1 to 9 pixels.
The start and end line defines the Y position of the first and last pixel line of the
scrolling range (end line > start line!) Only the last selected scrolling range is used!
3.6.3.5.2 Displays with vertical Resolution > 64 Pixels
Byte
1
Byte
2
Byte
3
Byte
4
Byte
5
Byte
6
Byte
7
Byte
8
Byte
9
Byte
10
Byte
11
ESC
Function
Direction
Speed
Increment
Start
line
hun-
dreds
Start
line
tens
Start
line
ones
End
line
hun-
dreds
End
line
tens
End
line
ones
1B
h
„S“
“0”: off
“1”: up
“2”: down
“0”: static
“1”: 1.8 sec
“9”: 0.2 sec
“1”: 1 pixel
“9”: 9 pixels
“0”: no
scrolling
“0” - “9”
“0” - “9” “0” - “9”
“0” - “9”
“0” - “9” “0” - “9”
This command scrolls once a screen area from the start line to the end line (speed
= “static”) or cyclically in steps of 1 to 9 pixels.
The start and end line defines the Y position of the first and last pixel line of the
scrolling range (end line > start line!) Only the last selected scrolling range is used!