migra MPB PB
Large Format, Graphics Compatible Display with Profibus Interface
Page 31
microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach
+49 9681 91960-0,
+49 9681 91960-10, [email protected], www.microsyst.de
3.10 Parallel Interface
Functions can be initialised via the 16 digital inputs, which are
analogous to the online frames used for the serial interface.
3.10.1 Timing at the Parallels Inputs
Data Bits 1-15
Strobe
Valid Data
10%
90%
24V
24V
0V
0V
Valid Data
>110ms
>110ms
>110ms
3.10.2 Input Levels at the parallel Inputs
Level
Voltage Range
U (low)
+ 0 to 1.6 V DC
U (high)
+ 18 to 30 V DC