调高器说明书
When the last 3 digits are
and the height value flashes,
it indicat
es anupper-limit ala
rm.
When the last 3 digit
s are
and the height value flashes, it
indicates a lower-limit alarm.
When the last 4 digits are
, it indicates
the upper limit
po
sit
ion is reached.
When the last 4 digits are
,
it
indicates t
he lower limit
po
sit
ion is reached.
Param
eter editing mode: The first
digit indicat
es the parameter name;
the second one indicates the equal sign
; t
he last 3 flashing digits
indicat
e the pa
rameter value(
In capacitance mode, it is a decimal
accurat
e to 0.1 mm; in arc voltage mode, it is a integer in V. The first
digit
is particularly
described as follows:
H:
the
upper
limit
value.
When
the
height
of
cutt
ing
torch
is
larger
than
t
his
value,
an
upper-limit
ala
rm
will
be
triggered.
In this case, the cutting torch can only move
down.
L:
lower
limit
value. When
the height is lower than this value,
it
is
a
lower-
limit
alarm
will
be
activated.
In
this
case,
the
cutting torch can only move up.
A:
the
set
value
of
height;
in
automatic
mode,
this
value
is
used as the given value fo
r automatic height adjustment.
E: Dead zone value (see 7.1).
D: Speed regulating zone value (see 7.1).
C: select
ion of detector mode (see 7.1).
b: No board descending
parameter value (see 7.1)
37