7
Key
Sign
Function
Shift
1. Use in combination with the confirm key to enter the
password interface;
2. Cursor movement during password input
Down
Number minus 1 or page down
Up
Number plus 1 or page up
Enter
Enter or exit
Function
Enter key for report, data reset and other functions
5.2
Key operation
The meter can enter the menu setting interface by simultaneously pressing the "shift" and "enter".
Customers can choose the corresponding password to enter the menu for operation according to
different needs. The meter password has two levels: level 1 password is 09454 and the level 2 password
is 19818. The authority of level 1 password is different from that of level 2 password. Level 2 password
has higher authority and more parameters can be changed. If customers need to modify level 1 or 2
password, it can be done in the secondary menu password modification item.
Note:
If you modify level 1 or level 2 password, please remember the modified password!
6
Parameter setting and method
6.1
Report query
In the main interface state (Figure 4), press (Function key) to enter the report query interface
(Figure 5), and then select the corresponding function to view the data according to actual needs.
Figure 5 Report query interface
Users can query 4 types of reports: daily, monthly, annual, and power outage reports. The meter can
save up to 90 daily reports, 36 monthly reports, 3 annual reports and 20 power outage reports.
6.2
Parameters setting
In the main interface state (Figure 4), press +
("shift" + "enter”) to enter the password input
interface (Figure 6). The user enters the corresponding password by entering passwords. The menu
sets the parameters related to the use of the flowmeter.
Special tips: Please operate carefully when setting, so as to avoid the failure of the flowmeter due to the
Day Report
Month Report
Year Report
Power Report