The Line and Client configuration modification can be performed at the same time and
applied at the same time with one reset. Traffic implications will depend on your choice
of reset.
Procedure
•
Ensure that the correct module is selected for management. Consult the object:
−
mgnt2GigmSelectedBoard
Location:…\microsens\mgnt2\mgnt2SNMPAgentData\
mgnt2ModulesManagement\
•
Change if necessary.
•
Determine a value corresponding to the configuration profile you require.
•
Perform an SNMP SET to write the value corresponding to the required
configuration profile into the SNMP agent.
•
Perform a SET to “on” the object:
−
ms430580mCfgWriteConfiguration
Location: ...\microsens\modulems430580m\ms430580mConfig\
This will load the new configuration from the SNMP agent to the modules RAM.
•
Transfer the new configuration into the module using the object:
−
ms430580mCtrlConfFlash
Location:
...\microsens\modulems430580m\ms430580mcontrolsWrite\ms430580mCtrlOther\
ms430580mCtrlsynth0\
•
Restart the module using a cold reset or by powering down/up to apply the
configuration modification. Reset information can be found in the Software
management section.
Note
At that point, configuration 2 becomes the default configuration of the MS
module.
End procedure
Management
Inventory
Accessing the inventory allows the user to obtain information on the modules current
hardware and software status. The objects described below may be found in:
…\microsens\modulems430580m\ms430580mri\
Note
Before consulting the inventory ensure that the correct module is selected.
Consult the object mgnt2GigmSelectedBoard