Media Converter/Signal Repeater
page 16/29
procedure describes the steps to follow to perform a hardware reset of the MS430580M
module.
Procedure
•
Using a flat head screwdriver, loosen the two holding screws on the frontplate,
located at the top right-hand and bottom left-hand corners.
•
Slide out the module for few centimetres
•
Wait for 15 seconds
Warning
The wait time of 15 seconds is mandato ry to insure to correct detection of the
module extraction and re-insertion. Re-inserting the MS430580M module to
early may casue communication problem between the MS430580M module and
the management board.
•
Slide in the module in the MS430500M chassis slot.
•
Check the module has been correctly detected by the MGNT board using the
object:
−
mgnt2GigmBoardTable
Location:
…\microsens\mgnt2\mgnt2SNMPAgentData\mgnt2ModulesManagement\
Note
Use the MS module series chassis User Manu al SNMP for details about this OID.
•
Using a flat head screwdriver; tighten the holding screw on the frontplate of
module.
End procedure
Software Cold Reset
A software cold reset loads the software from the selected bank and the configuration
into the operational memory. The configuration from conf2 is the first choice, if conf2
is empty then conf1; if conf1 is empty the default hardwired configuration is loaded.
This reset is traffic affecting and takes 20 seconds to complete. The following outlines
the steps to perform a Software cold reset on a MS430580M module:
Procedure
•
Ensure that the correct module is selected for management. Consult the object:
−
mgnt2GigmSelectedBoard
Location:
…\microsens\mgnt2\mgnt2SNMPAgentData\mgnt2ModulesManagement\
•
Change if necessary.
•
Start the reset:
MICROSENS