Media Converter/Signal Repeater
page 13/29
NAME
DESCRIPTION
ACTION
ms430580mAlmLine2TxBiasLowAla
TRSCV 2 Bias Low: Alarm
indicating that the transceiver
laser bias current of Line 2 is
lower than the threshold value
written in the transceiver
EEPROM
Correlate all Alarms. Carry out
necessary maintenance
procedures.
ms430580mAlmLine2TxBiasHighAla
TRSCV 2 Bias High: Alarm
indicating that the transceiver
laser bias current of Line 2 is
higher than the threshold value
written in the transceiver
EEPROM
Correlate all Alarms. Carry out
necessary maintenance
procedures.
ms430580mAlmLine2TempLowAla
TRSCV 2 Temp Low: Alarm
indicating that the transceiver
temperature of Line 2 is lower
than the threshold value written
in the transceiver EEPROM
Correlate all Alarms. Carry out
necessary maintenance
procedures.
ms430580mAlmLine2TempHighAla
TRSCV 2 Temp High: Alarm
indicating that the transceiver
temperature of Line 2 is higher
than the threshold value written
in the transceiver EEPROM
Correlate all Alarms. Carry out
necessary maintenance
procedures.
ms430580mAlmLine2RxPwrLowAla
TRSCV 2 Rx Power Low: Alarm
indicating that the transceiver
input power of Line 2 is lower
than the threshold value written
in the transceiver EEPROM
Correlate all Alarms. Carry out
necessary maintenance
procedures.
ms430580mAlmLine2RxPwrHighAla
TRSCV 2 Rx Power High: Alarm
indicating that the transceiver
input power of Line 2 is higher
than the thresholdvalue written in
the transceiverEEPROM
Correlate all Alarms. Carry out
necessary maintenance
procedures.
ms430580mAlmLine2TrscvAbsent
Line 2 SFP not plugged: This
OID indicates that the
transceiver module 2 is not
present
Plug in the Optical Module. If
Alarm
persists change the optical
component.
ms430580mAlmLine2TrscvDdmAbse
nt
DDM supported on Line 2 SFP: This
OID indicates that the
transceiver module 2 does not
support Digital Diagnostic
Monitoring Functions
If SFP supports DDM change the
SFP, else ignore.
ms430580mAlmLine2HwFail
Line 2 HW Failure: This OID
indicates a hardware failure on
the Line 2
Correlate relevant alarms. Carry
out
necessary maintenance
procedures.
ms430580mAlmLine2TrscvLsd
Line 2 SFP optical TX ON: This
OID indicates the optical output
power is off on Line 2
No action information only.
ms430580mAlmLine2TrscvDdmWarn
ing
Warning DDM on OpticalModule
2: This OID indicates awarning is
present coming outof optical
interface DDM onLine 2
Correlate all warnings. Carry out
necessary maintenance
procedures.
ms430580mAlmLine2TrscvDdmAlm
Alarm DDM on Optical Module 2:
This OID indicates an alarm is
present coming out of optical
interface DDM on Line 2
Correlate all alarms. Carry out
necessary maintenance
procedures.
MICROSENS
GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com