Microsens Media Converter/Signal Repeater Module User Manual Download Page 19

Media Converter/Signal Repeater

page 19/29

Location:..\microsens\modulems430580m\ms430580mmeasures\
ms430580mMesrLine\

Give the 3V3 voltage value of the SFP plugged into Line 1 and Line 2, read from the
Digital Diagnostic Monitoring (Unit = V). The following formula must be applied to the
returned value in order to obtain the actual voltage:

3V3 (Volts) = AV/10000

Parameter

Meaning 

Format

AV 

Article Value 

Unsigned word (16 bits)

For example:

A listing of the ms430580mMesrportaVolt outputs the following:

***** SNMP QUERY STARTED *****
1: ms430580mMesrportaVolt (integer) 33094
***** SNMP QUERY FINISHED *****
The value returned from the SFP in Line 1 is: 33094.
So applying the formula: 3V3 (Volts) = 33094/10000
Gives an actual value of: 3.3094V

Bias

The object:

ms430580mMesrportaTxBias

Location:..\microsens\modulems430580m\ms430580mmeasures\
ms430580mMesrClient\

The object:

ms430580mMesrportbTxBias

Location:..\microsens\modulems430580m\ms430580mmeasures\
ms430580mMesrLine\

Give the bias value of the SFP plugged into Line 1 and Line 2, read from the Digital
Diagnostic Monitoring (Unit = mA). The following formula must be applied to the
returned value in order to obtain the bias:

Bias(mA) = AV/500

Parameter

Meaning 

Format

AV 

Article Value 

Unsigned word (16 bits)

For example:

A listing of the ms430580mMesrportaTxBias outputs the following:
***** SNMP QUERY STARTED *****
1: ms430580mMesrportaTxBias (integer) 11046
***** SNMP QUERY FINISHED *****
The value returned from the SFP in Line 1 is: 11046.
So applying the formula: Bias(mA) = 11046/500
Gives an actual value of: 22.092mA

MICROSENS

 GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com

Summary of Contents for Media Converter/Signal Repeater Module

Page 1: ...management card Max 5x single size modules f ex 2x double size 1x single size module Hot swappable modules power supplies Redundant power supplies with 48 VDC input opt 230 VAC Exchangeable air and fi...

Page 2: ...rface Digital Diagnostic Monitoring information from SFP System description The block diagram for the MS430580M is given in Figure 1 The MS430580M is a bi directional device that offers twice the same...

Page 3: ...type used on Line 1 and Line 2 it is possible to perform together with the signal regeneration a media convertion 850nm to 1310nm CWDM to DWDM etc The following alarms are provided to the controller...

Page 4: ...a microprocessor associated with Flash and RAM memories The controller block collects information from different functional blocks and configures the HW according to a configuration file received The...

Page 5: ...580mConfig ms430580mCfgStartup ms430580mtableclientStartup The following table details the meaning of each bit as well as the default values ms430580mCfgportaTrscvCtrl Bit Default value Bit Name Descr...

Page 6: ...Description Bit 3 0 0000 Line 1 and Line 2 bitrate Bitrate selection 0 2 488 Gb s OC 48 STM16 1 1 25 Gb s GbE 2 622 08 Mb s OC 12 STM4 3 155 52 Mb s OC 3 STM1 4 2 125 Gb s 2GFC 5 1 0625 Gb s 1GFC 7 12...

Page 7: ...configuration from the SNMP agent to the modules RAM Transfer the new configuration into the module using the object ms430580mCtrlConfFlash Location microsens modulems430580m ms430580mcontrolsWrite m...

Page 8: ...AAA01 Release date yymmdd 060509 SW Part Number 3SW07001AAAA Version Number 02 Release date yymmdd 060510 ms430580mRinvPortASFP This object returns information relating to the Line 1 SFP in the Module...

Page 9: ...tenance procedures ms430580mAlmLine1TxBiasLowWng TRSCV 1 Bias Low warning Warning indicating that the transceiver laser bias current of Line 1 is lower than the threshold value written in the transcei...

Page 10: ...threshold value written in the transceiver EEPROM Correlate all Alarms Carry out necessary maintenance procedures ms430580mAlmLine1TxBiasLowAla TRSCV 1 Bias Low Alarm indicating that the transceiver...

Page 11: ...s ms430580mAlmLine1TrscvDdmAlm Alarm DDM on Optical Module 1 This OID indicates an alarm is present coming out of optical interface DDM on Line 1 Correlate all alarms Carry out necessary maintenance p...

Page 12: ...in the transceiver EEPROM Correlate all warnings Carry out necessary maintenance procedures ms430580mAlmLine2RxPwrHighWng TRSCV 2 Rx Power Highwarning Warning indicating that the transceiver input po...

Page 13: ...edures ms430580mAlmLine2RxPwrHighAla TRSCV 2 Rx Power High Alarm indicating that the transceiver input power of Line 2 is higher than the thresholdvalue written in the transceiverEEPROM Correlate all...

Page 14: ...nchronous event that the MGNT generates to indicate a status change e g a trap is generated on the detection of a start of an alarm and an end of an alarm Note It is important to set the IP address of...

Page 15: ...Carry out necessary maintenance procedures ms430580mPortbTrapNotUrgentGoesOff Not urgent Line 2 fault disappeared ms430580mAlmPortbTrscvDdmWarning ms430580mtrapBoardNumber No Action ms430580mPortbTrap...

Page 16: ...nt2 mgnt2SNMPAgentData mgnt2ModulesManagement Note Use the MS module series chassis User Manu al SNMP for details about this OID Using a flat head screwdriver tighten the holding screw on the frontpla...

Page 17: ...imately 20 seconds to complete Procedure Ensure that the correct module is selected for management Consult the object mgnt2GigmSelectedBoard Location microsens mgnt2 mgnt2SNMPAgentData mgnt2ModulesMan...

Page 18: ...gged into Line 1 and Line 2 read from the Digital Diagnostic Monitoring Unit C The following formula must be applied to the returned value in order to obtain the actual temperature T C MSB LSB 256 Par...

Page 19: ...3 3094V Bias The object ms430580mMesrportaTxBias Location microsens modulems430580m ms430580mmeasures ms430580mMesrClient The object ms430580mMesrportbTxBias Location microsens modulems430580m ms43058...

Page 20: ...le A listing of the ms430580mMesrportaTxPower outputs the following SNMP QUERY STARTED 1 ms430580mMesrportaTxPower integer 30 SNMP QUERY FINISHED The value returned from the SFP in Line 1 is 30 So app...

Page 21: ...tual value of 0 001mW And applying the formula Rx_Pwr dBm 10xlog 10 10000 Gives an actual value of 30dBm Appendixes Laser Class Laser Class Risks General Requirements 1 Considered safe to eye and Skin...

Page 22: ...shold value written in the transceiver EEPROM 1 3 6 1 4 1 20044 21 2 2 1 20 2 ms430580mAlmLine1TxPwrHighWng r TRSCV 1 Tx Power High warning Warning indicating that the transceiver output power of Line...

Page 23: ...is alarm reports the transmitter failure alarm generated by the transceivers 1 3 6 1 4 1 20044 21 2 2 3 16 4 ms430580mAlmLine1Los r Loss of Optical signal on Line 1 This OID indicates that no signal i...

Page 24: ...6 1 4 1 20044 21 2 3 2 ms430580mAlmLineUrg 1 3 6 1 4 1 20044 21 2 3 2 26 ms430580mAlmline2TrscvAlmDdm 1 3 6 1 4 1 20044 21 2 3 2 26 1 ms430580mAlmLine2TxPwrLowAla r TRSCV 2 Tx Power Low Alarm indicat...

Page 25: ...r Warning DDM on Optical Module 2 This OID indicates a warning is present coming out of optical interface DDM on Line 2 1 3 6 1 4 1 20044 21 2 3 3 7 10 ms430580mAlmLine2TrscvDdmAlm r Alarm DDM on Opt...

Page 26: ...value of the transceiver Line 2 read from the DDM Digital Diagnostic Monitoring Unit mA 1 3 6 1 4 1 20044 21 3 3 27 ms430580mMesrline2TxPower r Line 2 SFP Transmitted Power This OID gives the transmit...

Page 27: ...rscvOnoff r w Line 1 SFP Optical Laser OFF This OID switches off the transceiver on Line 1 1 3 6 1 4 1 20044 21 6 3 ms430580mCtrlLine 1 3 6 1 4 1 20044 21 6 3 24 ms430580mCtrlline2TrscvOnoff 1 3 6 1 4...

Page 28: ...e1TrapNotUrgentGoesOff n a Not urgent Line 1 default disappeared 1 3 6 1 4 1 20044 21 10 32 ms430580mLine1TrapUrgentGoesOn n a Urgent Line 1 default is activated 1 3 6 1 4 1 20044 21 10 33 ms430580mLi...

Page 29: ...al lost Fail Transmission failure Power consumption 8 W typical 10 W max Operating temperature 0 C to 50 C Storage temperature 20 C to 85 C Order Information Art No Description Connectors MS430580M 3R...

Reviews: