Microsens Media Converter/Signal Repeater Module User Manual Download Page 1

Overview

Media Converter/Signal Repeater module is a part of MICROSENS 10G Transport
Platform, a high performance and flexible carrier-class transmission system. The 10G
Transport Platform enables increasing transport capacitities in CWDM, DWDM and SDH
networks. The use of wide range TDM modules permits to reduce the number of
necessary wavelengths and to decrease the overall cost of the application. Ethernet
over SDH modules enable using exisiting SONET/SDH infractructure for IP transmission.

The general features of the system:

19“ 2U Chassis with 5 module slots and management card

Max. 5x single size modules f.ex. 2x double size + 1x single size module

Hot swappable modules & power supplies 

Redundant power supplies with -48 VDC input (opt. 230 VAC)

Exchangeable air- and filter module

Wide range of functional xWDM and TDM modules available

The functional modules of 10G Transport Platform include:

TDM 8x GBE or 8x GFC to 10G/OC-192/STM-64

TDM 5x GBE or 5x 2GFC to OC-192/STM-64

TDM 4x OC-48/STM-16 to 10G/OC-192/STM-64

TDM 2x GBE and 2x GFC to OC-48/STM-16

10G transponder with 3R, XFP and fixed Laser Versions

10G protocol converter 10G LAN to 10G WAN (OC-192/STM-64)

DWDM MUX/DeMUX, OADMs, EDFAs

MICROSENS

 GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com

MICROSENS

Media Converter/Signal Repeater
Module

Summary of Contents for Media Converter/Signal Repeater Module

Page 1: ...management card Max 5x single size modules f ex 2x double size 1x single size module Hot swappable modules power supplies Redundant power supplies with 48 VDC input opt 230 VAC Exchangeable air and fi...

Page 2: ...rface Digital Diagnostic Monitoring information from SFP System description The block diagram for the MS430580M is given in Figure 1 The MS430580M is a bi directional device that offers twice the same...

Page 3: ...type used on Line 1 and Line 2 it is possible to perform together with the signal regeneration a media convertion 850nm to 1310nm CWDM to DWDM etc The following alarms are provided to the controller...

Page 4: ...a microprocessor associated with Flash and RAM memories The controller block collects information from different functional blocks and configures the HW according to a configuration file received The...

Page 5: ...580mConfig ms430580mCfgStartup ms430580mtableclientStartup The following table details the meaning of each bit as well as the default values ms430580mCfgportaTrscvCtrl Bit Default value Bit Name Descr...

Page 6: ...Description Bit 3 0 0000 Line 1 and Line 2 bitrate Bitrate selection 0 2 488 Gb s OC 48 STM16 1 1 25 Gb s GbE 2 622 08 Mb s OC 12 STM4 3 155 52 Mb s OC 3 STM1 4 2 125 Gb s 2GFC 5 1 0625 Gb s 1GFC 7 12...

Page 7: ...configuration from the SNMP agent to the modules RAM Transfer the new configuration into the module using the object ms430580mCtrlConfFlash Location microsens modulems430580m ms430580mcontrolsWrite m...

Page 8: ...AAA01 Release date yymmdd 060509 SW Part Number 3SW07001AAAA Version Number 02 Release date yymmdd 060510 ms430580mRinvPortASFP This object returns information relating to the Line 1 SFP in the Module...

Page 9: ...tenance procedures ms430580mAlmLine1TxBiasLowWng TRSCV 1 Bias Low warning Warning indicating that the transceiver laser bias current of Line 1 is lower than the threshold value written in the transcei...

Page 10: ...threshold value written in the transceiver EEPROM Correlate all Alarms Carry out necessary maintenance procedures ms430580mAlmLine1TxBiasLowAla TRSCV 1 Bias Low Alarm indicating that the transceiver...

Page 11: ...s ms430580mAlmLine1TrscvDdmAlm Alarm DDM on Optical Module 1 This OID indicates an alarm is present coming out of optical interface DDM on Line 1 Correlate all alarms Carry out necessary maintenance p...

Page 12: ...in the transceiver EEPROM Correlate all warnings Carry out necessary maintenance procedures ms430580mAlmLine2RxPwrHighWng TRSCV 2 Rx Power Highwarning Warning indicating that the transceiver input po...

Page 13: ...edures ms430580mAlmLine2RxPwrHighAla TRSCV 2 Rx Power High Alarm indicating that the transceiver input power of Line 2 is higher than the thresholdvalue written in the transceiverEEPROM Correlate all...

Page 14: ...nchronous event that the MGNT generates to indicate a status change e g a trap is generated on the detection of a start of an alarm and an end of an alarm Note It is important to set the IP address of...

Page 15: ...Carry out necessary maintenance procedures ms430580mPortbTrapNotUrgentGoesOff Not urgent Line 2 fault disappeared ms430580mAlmPortbTrscvDdmWarning ms430580mtrapBoardNumber No Action ms430580mPortbTrap...

Page 16: ...nt2 mgnt2SNMPAgentData mgnt2ModulesManagement Note Use the MS module series chassis User Manu al SNMP for details about this OID Using a flat head screwdriver tighten the holding screw on the frontpla...

Page 17: ...imately 20 seconds to complete Procedure Ensure that the correct module is selected for management Consult the object mgnt2GigmSelectedBoard Location microsens mgnt2 mgnt2SNMPAgentData mgnt2ModulesMan...

Page 18: ...gged into Line 1 and Line 2 read from the Digital Diagnostic Monitoring Unit C The following formula must be applied to the returned value in order to obtain the actual temperature T C MSB LSB 256 Par...

Page 19: ...3 3094V Bias The object ms430580mMesrportaTxBias Location microsens modulems430580m ms430580mmeasures ms430580mMesrClient The object ms430580mMesrportbTxBias Location microsens modulems430580m ms43058...

Page 20: ...le A listing of the ms430580mMesrportaTxPower outputs the following SNMP QUERY STARTED 1 ms430580mMesrportaTxPower integer 30 SNMP QUERY FINISHED The value returned from the SFP in Line 1 is 30 So app...

Page 21: ...tual value of 0 001mW And applying the formula Rx_Pwr dBm 10xlog 10 10000 Gives an actual value of 30dBm Appendixes Laser Class Laser Class Risks General Requirements 1 Considered safe to eye and Skin...

Page 22: ...shold value written in the transceiver EEPROM 1 3 6 1 4 1 20044 21 2 2 1 20 2 ms430580mAlmLine1TxPwrHighWng r TRSCV 1 Tx Power High warning Warning indicating that the transceiver output power of Line...

Page 23: ...is alarm reports the transmitter failure alarm generated by the transceivers 1 3 6 1 4 1 20044 21 2 2 3 16 4 ms430580mAlmLine1Los r Loss of Optical signal on Line 1 This OID indicates that no signal i...

Page 24: ...6 1 4 1 20044 21 2 3 2 ms430580mAlmLineUrg 1 3 6 1 4 1 20044 21 2 3 2 26 ms430580mAlmline2TrscvAlmDdm 1 3 6 1 4 1 20044 21 2 3 2 26 1 ms430580mAlmLine2TxPwrLowAla r TRSCV 2 Tx Power Low Alarm indicat...

Page 25: ...r Warning DDM on Optical Module 2 This OID indicates a warning is present coming out of optical interface DDM on Line 2 1 3 6 1 4 1 20044 21 2 3 3 7 10 ms430580mAlmLine2TrscvDdmAlm r Alarm DDM on Opt...

Page 26: ...value of the transceiver Line 2 read from the DDM Digital Diagnostic Monitoring Unit mA 1 3 6 1 4 1 20044 21 3 3 27 ms430580mMesrline2TxPower r Line 2 SFP Transmitted Power This OID gives the transmit...

Page 27: ...rscvOnoff r w Line 1 SFP Optical Laser OFF This OID switches off the transceiver on Line 1 1 3 6 1 4 1 20044 21 6 3 ms430580mCtrlLine 1 3 6 1 4 1 20044 21 6 3 24 ms430580mCtrlline2TrscvOnoff 1 3 6 1 4...

Page 28: ...e1TrapNotUrgentGoesOff n a Not urgent Line 1 default disappeared 1 3 6 1 4 1 20044 21 10 32 ms430580mLine1TrapUrgentGoesOn n a Urgent Line 1 default is activated 1 3 6 1 4 1 20044 21 10 33 ms430580mLi...

Page 29: ...al lost Fail Transmission failure Power consumption 8 W typical 10 W max Operating temperature 0 C to 50 C Storage temperature 20 C to 85 C Order Information Art No Description Connectors MS430580M 3R...

Reviews: