Application Standards
An Application standard is a specific protocol established by a group or industry, such as the military,
hospitals, FDA, etc. Currently, the LVS-95XX Series supports the following Application standards:
AIAG / JAMA / JAPIA / ODETTE
ALDI
AS9132-A / AIM DPM Cat 0
Automatic GS1 or ISO
(read important note below)
Chinese Sensible (Han Xin) Code
DHL
FPMAJ
French
CIP
GS1 Data Matrix including NHRN
GS1
General
Specifications
GS1
(NTIN)
GS1 1D Report.doc and
GS1 2D Report.doc (requires the use of Microsoft®
Word).
GS1 1D Report.doc and GS1 2D Report.doc are the
default custom reports. You can create your own
custom report(s) by following the steps outlined in
Appendix G: Special Features (refer to the section
entitled “Custom Reports”).
HDMA
Guidelines
HIBC
IFAH
ISO/IEC
15415/15416
Italian
Pharmacode
Japanese
Codabar
Laetus
Pharmacode
MIL-STD-130
Miniature
Pharmacode
Multi-rotation Data Matrix
Multi-rotation QR Code
Postal (USPS IMB/Code 128, PostNet,
Japan Post)
PPN
Code
PZN-big, normal, small (German
Pharmacode)
PZN8
IMPORTANT:
When the “Postal (Intelligent Mail, PostNet, Japan Post)” Application
Standard is selected, the “SRP View” tab name changes to “Bar details” to provide an
analysis report of the postal barcode.
IMPORTANT note about Automatic GS1 or ISO Application standard:
When selecting the Automatic
GS1 or ISO standard, the following message appears. You must read the message, enter OK in the text
field, and then click OK.
The above Application standards vary according to specific industry norms. Failure to use the correct
standard causes the final grade to be incorrect. When no Application standard is specified, the ISO/IEC
15415/15416 should be used.