Page 5
Connect a suitable output cable from the appropriate video out connector to a monitor or other
display device. Make sure that the monitor (or other device) is correctly set to view that type of
video signal.
Other Connections
If you have a custom option installed which requires an external connection, please see the
supplement to this user guide for additional information.
Power Switch
The power switch is located in the lower right corner of the front panel. Pressing it once turns
the unit on, pressing it again turns the unit off. When off, the unit draws minimal power. All VMU
units will remember their settings when the power is turned off. More information is provided
later in this text.
Position Control 1
This rotary control will move the left or top cursor (depending on the setting of the X/Y switch) or
it will move both (same axis) cursors together if the track function is enabled.
Position Control 2
This rotary control will move the right or bottom cursor (depending on the setting of the X/Y
switch). If track mode is on, it will adjust the spread between the two (same axis) lines.
Lock Switch 1 and Lock Switch 2
Enabling the lock function will cause the related rotary position control to have no effect while
lock is on (indicated by the RED lamp below the switch). Lock functions are remembered
independently for the X and Y axes. A Lock override can be set in the menu system to lock a
control regardless of the switch setting (which will also be indicated by the light).
Track
Enabling the tracking function (lamp on) will cause the left position control to move both lines of
the same axis together (keeping the spacing constant). The right control will adjust the spacing
between the lines. When the tracking function is disabled (indicator extinguished), the two
controls will move the lines fully independently.
Position
The position set function allows the user to relocate the numeric display. Pressing the
CONTROLS & INDICATORS