background image

micro

HAM © 

2022

 

All rights reserved

TOGGLE 1-4 Type

TOGGLE 1-4

 is the simplest 

Type

, and items in its menu are present also in menus for other 

Types

A

 - this is a "live" visualization of current 

state of individual relays; relays' state can 
be toggled by clicking on the individual 
"buttons" or their names. If given ARXC is 
not present on the bus, this field is greyed 
out, although relays state can still be 
toggled and upon connecting the ARXC, 
relays will be switched accordingly.

B

 - each relay has an editable name, this is 

then used as a reference in Presets etc.

C

 - this is a live indication of ARXC internal 

temperature.

BCD-N Type

For 

BCD-N

 type, the menu window is slightly different:

A

 - the 

BCD-N

 group has an editable name, 

again used as reference to this group.

B

 - one of applications of 

BCD-N

 group is 

control of Four Square-type of antenna 
arrays, so if azimuth control is enabled for 

BCD-N

, the primary direction corresponding 

to 

number 

= 0 is North. Primary direction of 

subsequent values increases clockwise, by 
90º for 

BCD-2, 

by 45º for 

BCD-3, 

by 22.5º 

for 

BCD-4

C

 - the frame around individual relay status 

"buttons" indicates their grouping.

D

 - relays within the group don't have 

individual names, only the unused 

free

 relay has its own name (consequently, if 

BCD-4

 type is 

selected, there is no NAME row at all).

1-of-N Type

The menu window for 

1-of-N

 is similar:

According to the switching rule for 

1-of-N 

group, when 

1-of-N 

is selected in 

Menu→System→ARXCx, the first relay is 
automatically switched on. Contrary to 

BCD-N

, individual relays in 

1-of-N 

group do 

have individual names, as they can be used 
for individual Presets.

14

Summary of Contents for ARXC.LoRa

Page 1: ...microHAM 2022 All rights reserved ARXC ARCO External Control Accessories ARXC REL ARXC MAG ARXC LoRa microHAM www microham com microHAM s r o Maticna 28 92401 Galanta Slovakia v1 1 2022 1...

Page 2: ...Ra 3 2 ARXC HARDWARE SETUP 4 ARXC REL addressing 4 ARXC wiring 4 3 ARXC SOFTWARE SETUP 9 ARXC MAG Settings 9 Using ARXC MAG Sensor 10 ARXC REL Settings and Use 13 DECLARATION OF CONFORMITY 17 TRADEMAR...

Page 3: ...switches mast preamplifiers or anything what is suitable to be controlled from the ARCO user interface touch screen or VNC for Internet remote control ARCO uses preset buttons for relays control and...

Page 4: ...L module each module needs to have a unique address Address is set by combination of two DIP switches according to drawing on PC board next to DIP switch It is possible to set up to 4 different addres...

Page 5: ...l consumption including powered device is 500mA limited internally by ARCO It is ample power for ARXC devices alone but if provided power reserve is not enough for powering controlled devices use D SE...

Page 6: ...microHAM 2022 All rights reserved 6 ARCO connection to single ARXC REL and ARXC MAG ARCO connection to ARXC MAG...

Page 7: ...microHAM 2022 All rights reserved 7 ARCO connection to three ARXC REL and ARXC MAG...

Page 8: ...microHAM 2022 All rights reserved 8 Wireless ARCO connection to single ARXC REL and ARXC MAG using pair of ARXC LoRa...

Page 9: ...re continuously sampled and ARCO improves magnetic curve of the sensor ARXC MAG AZI Shows azimuth determined by ARXC MAG sensor SLIP CONTROL Enables or disables background checking if azimuth of main...

Page 10: ...licking on RESUME LEARNING button Note that disabling ARXC MAG at this point deletes the ARXC MAG calibration After transition to ACTIVE state it is recommended to store ARCO configuration to one of t...

Page 11: ...ck prerequisite Now in Menu Heading Calibration turn the rotator to at least 4 evenly spaced points by 90 i e North South East West and enter azimuth for these calibration points using CUSTOM button Y...

Page 12: ...ords LED is on if the general direction of terminal block of ARXC MAG is towards North Besides that LED indicates also presence or absence of communication from ARCO if ARCO communicates with ARXC MAG...

Page 13: ...n Menu System ARXCx In 1 of N there is always exactly one relay switched on This rule is enforced even when controlling relays in the ARXC Control window and in Menu System ARXCx Individual relays can...

Page 14: ...ditable name again used as reference to this group B one of applications of BCD N group is control of Four Square type of antenna arrays so if azimuth control is enabled for BCD N the primary directio...

Page 15: ...NTENNA 2 an ARXC group with the name 1OF3 1 is selected for ANTENNA 3 the pull down is opened and displays the list of available options If ARXC group is selected instead of ANTENNA x its name is give...

Page 16: ...nsequently in this window the individual or the common set of Presets is edited B exit from this window without changing the given Preset All other buttons in this window represent possible options to...

Page 17: ...orward backward buttons instead of individual relays control and in between them the current value or if azimuth control is enabled for given group the current primary direction is displayed DECLARATI...

Reviews: