background image

micro

HAM © 

2022

 

All rights reserved

ARXC

ARCO External Control 

Accessories

ARXC.REL

ARXC.MAG

ARXC.LoRa

micro

HAM

www.microham.com

microHAM s.r.o.

Maticna 28

92401 Galanta

Slovakia

v1.1

2022

1

Summary of Contents for ARXC.LoRa

Page 1: ...microHAM 2022 All rights reserved ARXC ARCO External Control Accessories ARXC REL ARXC MAG ARXC LoRa microHAM www microham com microHAM s r o Maticna 28 92401 Galanta Slovakia v1 1 2022 1...

Page 2: ...Ra 3 2 ARXC HARDWARE SETUP 4 ARXC REL addressing 4 ARXC wiring 4 3 ARXC SOFTWARE SETUP 9 ARXC MAG Settings 9 Using ARXC MAG Sensor 10 ARXC REL Settings and Use 13 DECLARATION OF CONFORMITY 17 TRADEMAR...

Page 3: ...switches mast preamplifiers or anything what is suitable to be controlled from the ARCO user interface touch screen or VNC for Internet remote control ARCO uses preset buttons for relays control and...

Page 4: ...L module each module needs to have a unique address Address is set by combination of two DIP switches according to drawing on PC board next to DIP switch It is possible to set up to 4 different addres...

Page 5: ...l consumption including powered device is 500mA limited internally by ARCO It is ample power for ARXC devices alone but if provided power reserve is not enough for powering controlled devices use D SE...

Page 6: ...microHAM 2022 All rights reserved 6 ARCO connection to single ARXC REL and ARXC MAG ARCO connection to ARXC MAG...

Page 7: ...microHAM 2022 All rights reserved 7 ARCO connection to three ARXC REL and ARXC MAG...

Page 8: ...microHAM 2022 All rights reserved 8 Wireless ARCO connection to single ARXC REL and ARXC MAG using pair of ARXC LoRa...

Page 9: ...re continuously sampled and ARCO improves magnetic curve of the sensor ARXC MAG AZI Shows azimuth determined by ARXC MAG sensor SLIP CONTROL Enables or disables background checking if azimuth of main...

Page 10: ...licking on RESUME LEARNING button Note that disabling ARXC MAG at this point deletes the ARXC MAG calibration After transition to ACTIVE state it is recommended to store ARCO configuration to one of t...

Page 11: ...ck prerequisite Now in Menu Heading Calibration turn the rotator to at least 4 evenly spaced points by 90 i e North South East West and enter azimuth for these calibration points using CUSTOM button Y...

Page 12: ...ords LED is on if the general direction of terminal block of ARXC MAG is towards North Besides that LED indicates also presence or absence of communication from ARCO if ARCO communicates with ARXC MAG...

Page 13: ...n Menu System ARXCx In 1 of N there is always exactly one relay switched on This rule is enforced even when controlling relays in the ARXC Control window and in Menu System ARXCx Individual relays can...

Page 14: ...ditable name again used as reference to this group B one of applications of BCD N group is control of Four Square type of antenna arrays so if azimuth control is enabled for BCD N the primary directio...

Page 15: ...NTENNA 2 an ARXC group with the name 1OF3 1 is selected for ANTENNA 3 the pull down is opened and displays the list of available options If ARXC group is selected instead of ANTENNA x its name is give...

Page 16: ...nsequently in this window the individual or the common set of Presets is edited B exit from this window without changing the given Preset All other buttons in this window represent possible options to...

Page 17: ...orward backward buttons instead of individual relays control and in between them the current value or if azimuth control is enabled for given group the current primary direction is displayed DECLARATI...

Reviews: