Ethernet (RJ45) Cable Specifications and Pin Assignments 

 

 

 

Figure 3 

 

Table 8 - Cable Specification 

Cable Type 

Max. 

Length 

Connector 

10BASE-T 

Cat. 3, 4, 5 100-ohm UTP 

100 m (328 ft) 

RJ45 

 
 

Table 9 - J1 Ethernet 

Pin 

Number 

MDI Signal Name 

MDI-X Signal Name 

Transmit Data (TD+) 

Receive Data (RD+) 

Transmit Data (TD-) 

Receive Data (RD-) 

Receive Data (RD+) 

Transmit Data (TD+) 

Receive Data (RD-) 

Transmit Data (TD-) 

Pins 4, 5, 7, and 8 are not connected. 

 

 

Table 10 

Straight-Through 

RJ-45 Pin 

Assignments 

End 1 

End 2 

1 (TD+) 

1 (TD+) 

2 (TD-) 

2 (TD-) 

3 (RD+) 

3 (RD+) 

6 (RD-) 

6 (RD-) 

 

Table 11 

Crossover RJ-45 

Pin Assignments 

End 1 

End 2 

1 (TD+) 

3 (RD+) 

2 (TD-) 

6 (RD-) 

3 (RD+) 

1 (TD+) 

6 (RD-) 

2 (TD-) 

 
 

MicroGate™ User Manual                                                                                                11 

Summary of Contents for MicroGate MG1-1000

Page 1: ...MicroGate Online Kitchen Gateway User Guide MG1 1000 January 2005 Part Number 4911000 010 Revision Number A3 MicroGate User Manual 1...

Page 2: ...6 III HARDWARE DESCRIPTION 7 LED INDICATORS 8 POWER CONNECTORS PIN ASSIGNMENT 8 RS232 SERIAL PORT PIN ASSIGNMENT 9 RS485 SERIAL PORT PIN ASSIGNMENT 9 ETHERNET RJ45 CABLE SPECIFICATIONS AND PIN ASSIGNM...

Page 3: ...all essential networking functions including a full featured TCP IP stack 10Base T Ethernet connection real time operating system embedded Web Server optional modem and battery backed memory Feature R...

Page 4: ...rise Raptor Web Software equipment manufacturers systems integrators and IT professionals have a total Online Kitchen system to help manage a fully integrated restaurant Never before has there been su...

Page 5: ...Control Signals for CMOS and RS232 only RTS CTS DTR DSR and DCD Protocols MODBUS RTU MODBUS ASCII BACNET or any custom proprietary protocol Network Interface Interface 10Base T Ethernet IEEE 802 3 Co...

Page 6: ...ity Maximum 95 Relative Humidity non condensing Altitude 10 000 ft 3048 m max Physical Specifications TOLERANCES 010 Inches 4701000A1 Figure 1 Without Modem Dimensions 4 75x3 00x0 80 inches 120 7x76 2...

Page 7: ...5 Connects gateway to the Internet LAN or WAN J2 Modem Port Optional Modem Port RJ11 Connects gateway to the Internet or an external PC using a telephone line Optional J3 Power Connector Supplies 5V p...

Page 8: ...ing 1 sec rate Gateway is alive and running On The MicroGate is receiving power DS4 Power green Off The MicroGate is not receiving power Power Connectors Pin Assignment Table 3 J3 Power Connector Pin...

Page 9: ...in Option must be specified when ordering Input RS485 Serial Port Pin Assignment Table 6 J7 RS485 Channel 1 Pin Number Name Description Type 1 RS485_RX Non Inverting Receiver Input Full Duplex Mode In...

Page 10: ...ode Input 6 RS485_GND RS485 Ground Not signal Ground Power RS485_TX Non Inverting Driver Output Full Duplex mode Output 8 RS485_TX RX Non Inverting Receiver Input Driver Output Half Duplex mode Input...

Page 11: ...Name MDI X Signal Name 1 Transmit Data TD Receive Data RD 2 Transmit Data TD Receive Data RD 3 Receive Data RD Transmit Data TD 6 Receive Data RD Transmit Data TD Pins 4 5 7 and 8 are not connected Ta...

Page 12: ...cation in the kitchen or office No special cooling requirements are needed but you should keep the MicroGate away from any heating device dusty or wet environments If the MicroGate needs to operate in...

Page 13: ...ng for E Control Systems units on your network Note This could take up to 30 seconds to complete Figure 5 3 A list of all of the ECS units on the network is listed sorted by their MAC Address see Figu...

Page 14: ...Figure 6 4 Once the row corresponding to the unit to be configured is highlighted click on Edit Unit see Figure 6 note 1 to bring up the Unit s Properties Figure 7 MicroGate User Manual 14...

Page 15: ...l see DS3 stop flashing When it starts flashing again you are done configuring the MicroGate Note You can also verify that the MicroGate s configuration changed by clicking on Start Discovery see Figu...

Page 16: ...2 Boxed enclosure Shrouded Keyed Vertical Mount Wire or Ribbon Type Connector for RS232 1 and RS232 2 Shrouded Keyed Vertical Mount Wire or Ribbon Type Connector for RS485 1 and RS485 2 Shrouded Keyed...

Page 17: ...prior to returning any product to ECS Proof of purchase may be required Any product returned to ECS without a valid Return Material Authorization RMA number clearly marked on the outside of the packag...

Page 18: ...eControlSystems com before you start installing the equipment All information is subject to change without notice Limitation of Liability In no event whether based in contract or tort including neglig...

Reviews: