background image

VI. Limited Warranties 

 

E-Control Systems' Limited Warranty Statement 

Limited Warranty Statement: E-Control Systems ("ECS") warrants its products to be free from 
defects in workmanship and materials, under normal use and service, for the applicable warranty 
term. All ECS products carry a standard 1 year limited warranty from the date of purchase from 
ECS or its Authorized Reseller/Distributors. ECS may, at its own discretion, repair or replace any 
product not operating as warranted with a similar or functionally equivalent product, during the 
applicable warranty term. ECS will endeavor to repair or replace any product returned under 
warranty within 30 days of receipt of the product. As new technologies emerge, older 
technologies become obsolete and ECS will, at its discretion, replace an older product in its 
product line with one that incorporates these newer technologies 
 
All products that are replaced become the property of ECS. Replacement products may be either 
new or reconditioned. Any replaced or repaired product carries, either a 30-day limited warranty 
or the remainder of the initial warranty, whichever is longer. ECS is not responsible for any 
custom software or firmware, configuration information, or memory data of Customer contained 
in, stored on, or integrated with any products returned to ECS pursuant to any warranty. Products 
returned to ECS should have any customer-installed accessory or add-on components, such as 
expansion modules, removed prior to returning the product for replacement. ECS is not 
responsible for these items if they are returned with the product. Customers must contact ECS for 
a Return Material Authorization number prior to returning any product to ECS. Proof of purchase 
may be required. Any product returned to ECS without a valid Return Material Authorization 
(RMA) number clearly marked on the outside of the package will be returned to customer at 
customer’s expense. Customers are responsible for all shipping charges from their facility to 
ECS. ECS is responsible for return shipping charges from ECS to customer. 
 

WARRANTIES EXCLUSIVE: 

IF A ECS PRODUCT DOES NOT OPERATE AS 

WARRANTED ABOVE, CUSTOMER'S SOLE REMEDY SHALL BE REPAIR OR 
REPLACEMENT OF THE PRODUCT IN QUESTION, AT ECS’ OPTION. THE FOREGOING 
WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER 
WARRANTIES OR CONDITIONS, EXPRESSED OR IMPLIED, EITHER IN FACT OR BY 
OPERATION OF LAW, STATUTORY OR OTHERWISE, INCLUDING WARRANTIES OR 
CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. 
ECS NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR 
IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE, INSTALLATION, 
MAINTENANCE OR USE OF ITS PRODUCTS. ECS SHALL NOT BE LIABLE UNDER 
THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THE ALLEGED 
DEFECT IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUSTOMER'S OR 
ANY THIRD PERSON'S MISUSE, NEGLECT, IMPROPER INSTALLATION OR TESTING, 
UNAUTHORIZED ATTEMPTS TO REPAIR, OR ANY OTHER CAUSE BEYOND THE 
RANGE OF THE INTENDED USE, OR BY ACCIDENT, FIRE, LIGHTNING, OR OTHER 
HAZARD. LIMITATION OF LIABILITY: IN NO EVENT, WHETHER BASED IN 
CONTRACT OR TORT (INCLUDING NEGLIGENCE), SHALL ECS BE LIABLE FOR 
INCIDENTAL, CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES OF 
ANY KIND, OR FOR LOSS OF REVENUE, LOSS OF BUSINESS, OR OTHER FINANCIAL 
LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE, INSTALLATION, 
MAINTENANCE, USE, PERFORMANCE, FAILURE, OR INTERRUPTION OF ITS 
PRODUCTS, EVEN IF ECS OR ITS AUTHORIZED RESELLER/DISTRIBUTOR HAS BEEN 

MicroGate™ User Manual                                                                                                17 

Summary of Contents for MicroGate MG1-1000

Page 1: ...MicroGate Online Kitchen Gateway User Guide MG1 1000 January 2005 Part Number 4911000 010 Revision Number A3 MicroGate User Manual 1...

Page 2: ...6 III HARDWARE DESCRIPTION 7 LED INDICATORS 8 POWER CONNECTORS PIN ASSIGNMENT 8 RS232 SERIAL PORT PIN ASSIGNMENT 9 RS485 SERIAL PORT PIN ASSIGNMENT 9 ETHERNET RJ45 CABLE SPECIFICATIONS AND PIN ASSIGNM...

Page 3: ...all essential networking functions including a full featured TCP IP stack 10Base T Ethernet connection real time operating system embedded Web Server optional modem and battery backed memory Feature R...

Page 4: ...rise Raptor Web Software equipment manufacturers systems integrators and IT professionals have a total Online Kitchen system to help manage a fully integrated restaurant Never before has there been su...

Page 5: ...Control Signals for CMOS and RS232 only RTS CTS DTR DSR and DCD Protocols MODBUS RTU MODBUS ASCII BACNET or any custom proprietary protocol Network Interface Interface 10Base T Ethernet IEEE 802 3 Co...

Page 6: ...ity Maximum 95 Relative Humidity non condensing Altitude 10 000 ft 3048 m max Physical Specifications TOLERANCES 010 Inches 4701000A1 Figure 1 Without Modem Dimensions 4 75x3 00x0 80 inches 120 7x76 2...

Page 7: ...5 Connects gateway to the Internet LAN or WAN J2 Modem Port Optional Modem Port RJ11 Connects gateway to the Internet or an external PC using a telephone line Optional J3 Power Connector Supplies 5V p...

Page 8: ...ing 1 sec rate Gateway is alive and running On The MicroGate is receiving power DS4 Power green Off The MicroGate is not receiving power Power Connectors Pin Assignment Table 3 J3 Power Connector Pin...

Page 9: ...in Option must be specified when ordering Input RS485 Serial Port Pin Assignment Table 6 J7 RS485 Channel 1 Pin Number Name Description Type 1 RS485_RX Non Inverting Receiver Input Full Duplex Mode In...

Page 10: ...ode Input 6 RS485_GND RS485 Ground Not signal Ground Power RS485_TX Non Inverting Driver Output Full Duplex mode Output 8 RS485_TX RX Non Inverting Receiver Input Driver Output Half Duplex mode Input...

Page 11: ...Name MDI X Signal Name 1 Transmit Data TD Receive Data RD 2 Transmit Data TD Receive Data RD 3 Receive Data RD Transmit Data TD 6 Receive Data RD Transmit Data TD Pins 4 5 7 and 8 are not connected Ta...

Page 12: ...cation in the kitchen or office No special cooling requirements are needed but you should keep the MicroGate away from any heating device dusty or wet environments If the MicroGate needs to operate in...

Page 13: ...ng for E Control Systems units on your network Note This could take up to 30 seconds to complete Figure 5 3 A list of all of the ECS units on the network is listed sorted by their MAC Address see Figu...

Page 14: ...Figure 6 4 Once the row corresponding to the unit to be configured is highlighted click on Edit Unit see Figure 6 note 1 to bring up the Unit s Properties Figure 7 MicroGate User Manual 14...

Page 15: ...l see DS3 stop flashing When it starts flashing again you are done configuring the MicroGate Note You can also verify that the MicroGate s configuration changed by clicking on Start Discovery see Figu...

Page 16: ...2 Boxed enclosure Shrouded Keyed Vertical Mount Wire or Ribbon Type Connector for RS232 1 and RS232 2 Shrouded Keyed Vertical Mount Wire or Ribbon Type Connector for RS485 1 and RS485 2 Shrouded Keyed...

Page 17: ...prior to returning any product to ECS Proof of purchase may be required Any product returned to ECS without a valid Return Material Authorization RMA number clearly marked on the outside of the packag...

Page 18: ...eControlSystems com before you start installing the equipment All information is subject to change without notice Limitation of Liability In no event whether based in contract or tort including neglig...

Reviews: