Chapter 5
Printer Commands
))))))))))))))))))))))))))))))))))))))))))))
))))))))))))))))))))))))))))))))))))))))))))
410 Operators Manual
45
5.3.4 REAL-TIME CLOCK
^A
^D
Command
30
Change Clock: Use the sequence below to set the time and date of the optional
real-time socket:
^D30
<CR>
HH:MM:SS
<CR>
DD/MN/YR/W
<CR>
Where the above parameters are defined as:
HH
= hours (24 hour format)
DD
= day
MM
= minutes
MN
= month
SS
= seconds
YR
= last 2 of year
W
= day of the week
1
= SUN
2
= MON
3
= TUE
4
= WED
5
= THR
6
= FRI
7
= SAT
The optional clock chip produces a string of data that is accessed through use of a TSN
of 0 and a TSP dependent on the data required of the clock chip.
The data string is shown below...
HH:MM:SS MN/DD/YR XXX DD/MN/YR XXX
...where xxx is the day of the week.
These values should be inserted into the Field parameters for proper clock text access:
Clock Field Parameters
TSN
TSP
CC
DATA
0
1
8
HH:MM:SS
0
10
8
MN/DD/YR
0
19
3
Day of Week
0
23
8
DD/MN/YR
0
32
3
Day of Week
Table 10
Summary of Contents for 410