Programming the MPPT
BATTERY PACK SELECT
12
– 48 AUTO SELECT
press CHRG to save
press DATA to change
CHARGE LIMIT IS @
=
95%
press CHRG to save
press DATA to change
EXTERNAL OUTPUT IS A
UNUSED OUTPUT
N/C
press CHARGE to save
press DATA to change
SET OPERATION MODE
F MODE0
press CHRG to save
press DATA to change
SOLAR OR WIND MPPT ?
MODE = SOLAR
press CHRG to save
press DATA to change
The display changes to: BATTERY PACK SELECT
8.6
Battery Set Voltage
This allows the MPPT to auto select the battery system or the
MPPT can be PRESET.
•
AUTO
•
12 volt, 24volt, 36volt, 48 volt battery pack.
•
Default Value is 12
– 48 AUTO SELECT.
➢
Press the
<DATA>
button to change the BATTERY PACK SELECT
➢
Press the
<CHARGE> button
to save the setting
The screen changes to: CHARGE LIMIT
8.7
Charge Limit
This allows the user to limit the MPPT current.
100 % will be 20 amps or if the limit must be 18 amps then set
the % to 90 % for a 20Amp MPPT as an example.
The charge limit can be set in 5% increments. 0% - 100%.
This can be extended to any LCD MPPT type accordingly.
Default Value is 95%.
➢
Press the
<DATA>
button to change the battery CHARGE LIMIT
➢
Press
<CHARGE>
to save the setting.
The screen changes to: EXTERNAL OUTPUT
8.8
External Output Connections:
Please refer to Section 9 : External Output Connections.
The screen changes to: SET OPERATION MODE
8.9
Set Operation Mode
MODE 0 is the Low Frequency Setting
– 34MHz.
MODE 1 is the High Frequency Setting
– 77MHz.
MODE 2
– 5 Is Currently Not Used.
•
Default Value is MODE 0.
➢
Press the
<DATA>
button to change the OPERATION MODE
➢
Press the
<CHARGE> button
to save the setting
The screen changes to: SOLAR OR WIND
8.10 Solar or Wind Settings
This Setting allows the MPPT to be changed between a
solar MPPT and a Wind Turbine MPPT.
Please confirm that these settings are not adjusted as a
standard.
Confirm with support before adjusting these settings.
Default Value is SOLAR
➢
Press the
<DATA>
button to change the SOLAR OR WIND SETTINGS