RETURN PROCEDURE

The MicroAire LipoTower System is field-repairable only, and should not be returned to the factory.

WARRANTY

MicroAire Surgical Instruments warrants its LipoTower System to be free from defects in material and workmanship 
in their manufacture for a period of one year from the original purchase date by the end customer. The warranty is 
limited to the repair or replacement of the product without charge.

This warranty is void in the event of abuse, misuse, or use in other than normal surgical environments, or in the 
event of disassembly, alteration, or repair of the product not authorized by the manufacturer, or in the event that the 
product has not been used in a reasonable manner and in compliance with the written instructions furnished by the 
manufacturer.

All other expressed or implied warranties of fitness and merchantability are excluded here from, and the manufacturer 
shall have no liability of any kind for incidental or consequential damages.

EXTENDED WARRANTY/SERVICE AGREEMENT

Extended warranties and service agreements are available on MicroAire power equipment. Extended warranties may 
be purchased while the equipment is covered by the original warranty. If the equipment is out of warranty, it must first 
be restored, if necessary, to full serviceable condition before being eligible for a service agreement.

DISPOSAL

Follow local regulations for proper disposal.

IEC 60601-1-2 COMPLIANCE SUMMARY

CAUTION: 

The MicroAire LipoTower system needs to be installed and put into service according to the EMC 

information provided in this Instructions for Use manual. Portable and mobile RF communications equipment can 
affect medical electrical equipment. The MicroAire LipoTower System may be interfered with by other equipment with 
CISPR emission requirements.

CAUTION: 

The pin of the BNC connector of the MicroAire LipoTower System should not be touched and connection to 

this port should not be made unless ESD precautionary procedures are used.

CAUTION: 

Electrostatic Discharge (ESD) can damage electronic equipment.  Under certain conditions, ESD may build 

up on your body or an object and then discharge into another object. To prevent ESD damage, you should discharge 
static electricity from your body before interacting with the MicroAire LipoTower System.  You can protect against 
static-electricity discharge from your body by touching a metal grounded object before you interact with anything 
electronic.  It is recommended that all staff involved with this device receive an explanation of the ESD warning 
symbol and training in ESD precautionary procedures.

CAUTION: 

The use of accessories and cables other than those specified in the Accessories list of this Instructions for 

Use manual may result in increased emissions or decreased immunity of the equipment or system.

CAUTION: 

The MicroAire LipoTower system should not be used adjacent to or stacked with other equipment and that 

if adjacent or stacked use is necessary, the equipment or system must be observed to verify normal operation in the 
configuration in which it will be used. 

Summary of Contents for ASP-1021

Page 1: ...MicroAire LipoTower System Instructions for Use...

Page 2: ...nsole for PAL REF 5025 Electric Power Console for MicroAire Instruments REF PAL 1200 Liposuction Tubing 12 foot REF 1006 PALE PAL Instrument Cable for REF 1020 1025 REF 5006 PAL PAL Instrument Cable f...

Page 3: ...nd the 5020 5025 Electric Console are described in their respective IFUs This IFU addresses primarily the operation maintenance cleaning and sterilization procedures applicable to the MicroAire LipoTo...

Page 4: ...nd or postoperative hemodynamic stability and patient safety The capability of providing adequate timely replacement is essential for patient safety WARNING Grounding reliability can only be achieved...

Page 5: ...system on another patient CAUTION Federal Law restricts this device to sale by or on the order of a physician or properly licensed practitioner CAUTION See PAL 650 Instrument System Instruction Manual...

Page 6: ...CH ON allows pumps to be activated by the Control Switch STANDBY o turns vacuum pumps off 6 STORAGE BASKET 7 LOCKING CASTERS 8 PUSH HANDLE 9 MAIN VACUUM CONNECTION 10 REAR STORAGE BASKET 11 POWER INLE...

Page 7: ...20 1025 or REF 5020 through the cable opening and connect it to the hospital grade outlet on the back of the cart Figure 6 4 Manuever the BNC cable from the REF 1020 1025 or REF 5020 through the cable...

Page 8: ...er Rack on the top of the cart Slide one or more Waste Canister Rings REF ASP RNG 1200 or REF ASP RNG 2000 into any of the four available canister slots These slots also accept various wall mount styl...

Page 9: ...or to use all system components should be inspected to detect any damage excessive wear corrosion or malfunction DO NOT use if any potential problems become apparent Contact MicroAire for resolution W...

Page 10: ...PRESSURE ADJUSTMENT knob controls the amount of suction pressure Vacuum pressure is displayed on the LCD screen Suction is increased by turning the knob clockwise towards MAX and suction is decreased...

Page 11: ...N OPTIONAL INSTALLING THE TUMESCENT MODULE 1 Turn off power and disconnect main power by unplugging power cord 2 Locate the Tumescent Bay cover on the left side of the cart Remove the the two retainin...

Page 12: ...the foot switch still does not operate properly contact MicroAire Customer Service for additional troubleshooting and repair VACUUM PRESSURE IS INSUFFICIENT Ensure all aspiration canisters and aspira...

Page 13: ...roAire LipoTower System is operated at high elevation or low atmospheric pressure aspiration performance may be adversely affected NOISE LEVEL EXPOSURE LIMITS The A weighted emission sound pressure le...

Page 14: ...SUMMARY CAUTION The MicroAire LipoTower system needs to be installed and put into service according to the EMC information provided in this Instructions for Use manual Portable and mobile RF communica...

Page 15: ...IM LIPOTOWER Rev G 15 Table 1 IEC 60601 1 2 Table 201 Table 2 IEC 60601 1 2 Table 202...

Page 16: ...IM LIPOTOWER Rev G 16 Table 4 IEC 60601 1 2 Table 206 Table 3 IEC 60601 1 2 Table 204...

Page 17: ...IM LIPOTOWER Rev G 17 NOTES...

Page 18: ...IM LIPOTOWER Rev G 18 NOTES...

Page 19: ...IM LIPOTOWER Rev G 19 NOTES...

Page 20: ...nstruments LLC IM LIPOTOWER Rev G Printed in the USA M MicroAire Surgical Instruments LLC 3590 Grand Forks Blvd Charlottesville VA 22911 USA Telephone 800 722 0822 434 975 8000 Fax 800 648 4309 434 97...

Reviews: