Page 8
surfaceCONTROL 3D SC2500 / SC2510
9.
Operation
Initial Operation
The sensor and the controller may only be connected to peripherals
when they do not carry power, that is, only when the supply voltage
has been switched off.
Mount the sensor according to the assembly instructions.
Mount the controller as per the assembly instructions.
Connect the sensor and the controller to the cable harness included in the delivery.
Connect the controller to the PC. To do so, use a common Ethernet cable of category
CAT5e or higher.
Connect the sensor to the power supply.
Connect the controller to the power supply
Turning On
Switch on the power supply (24 VDC) on the controller.
Press the
Power
button on the controller.
TX1
Power
2
1
RX1
TX2
RX2
The
Power
LED on the controller is illuminated red if the power supply is sufficient, and
green after pressing the Power button.
It starts when the supply voltage is applied.
i
The surfaceCONTROL 3D 25x0 sensor requires a warm-up time of typically 60 min-
utes for precise measurements.