5. 

Light Source

The surfaceCONTROL 3D 25x0 sensor works with an LED lighting unit. Measurement is 
performed using blue light at the dominant 462 nm wavelength. The sensor is included in 
risk group 2 according to EN 62471: 2008.

Do not look into the lens. Consciously close your eyes or im-
mediately turn away if the optical radiation enters the eye.

The warning sign below is attached to the front side:

Fig. 1 LED warning sign

i

  If the information sign is covered over when the unit is installed, the user must en-

sure that a supplementary information sign is attached at the installation location.

Summary of Contents for surfaceCONTROL 3D SC2500

Page 1: ...the controller Do not touch the protective windows Remove any fingerprints immediately using pure alcohol and a clean cotton cloth without leaving any streaks Protect the cables against damage Failur...

Page 2: ...Controller 40 85 C Humidity 20 80 non condensing Ambient pressure Atmospheric pressure 1 Max permissible operating temperature with 0 7 m s air blow 4 Unpacking Included in Delivery 1 Sensor surfaceCO...

Page 3: ...uded in risk group 2 according to EN 62471 2008 Do not look into the lens Consciously close your eyes or im mediately turn away if the optical radiation enters the eye The warning sign below is attach...

Page 4: ...e connector panel on the rear side 1 2 3 4 1 Ethernet port Camera 1 2 Ethernet port Camera 2 3 Sensor control 4 Power supply Fig 2 Rear view of sensor with connectors Supply Voltage Power Pin Signal C...

Page 5: ...Pin assignment connector Ethernet port For the image data output of the cameras via Gigabit Ethernet the sensor has two Gigabit Ethernet interfaces The sensor supports only the transmission with 1 Gbi...

Page 6: ...roller front view with connectors Supply voltage Power The power supply connection is a 4 pin plug connector Pin Designation Comment 9 V 36 V DC nominal value 24 V max power consumption 112 W 0 V Fig...

Page 7: ...Dismantling Proceed as follows if you would like to detach the sensor from the tripod again Only for column stand option with boom Secure the boom of the tripod with the help of the clamping lever or...

Page 8: ...the delivery Connect the controller to the PC To do so use a common Ethernet cable of category CAT5e or higher Connect the sensor to the power supply Connect the controller to the power supply Turning...

Page 9: ...red for this 4 Connect the controller of the surfaceCONTROL 3D 25x0 measuring system to the PC via Ethernet Do not use hubs i If your network card supports the VLAN option this option must be disabled...

Page 10: ...the surface of the test object Alignment with Crosshair You will achieve the best results in the mid of the measurement area focal range of cam eras In the main view switch from the 3D View to the Im...

Page 11: ...ere created with the 3DInspect software from Micro Epsilon 14 Disclaimer All components of the device have been checked and tested for functionality in the factory However should any defects occur des...

Page 12: ...ess is defec tive If possible save the current sensor settings in a parameter set to reload them into the sensor after the repair Please send us the affected parts for repair or exchange If the cause...