MICRO-EPSILON surfaceCONTROL 3D SC2500 Assembly Instructions Manual Download Page 2

Page 2

surfaceCONTROL 3D SC2500 / SC2510

3. 

Proper Environment

 - Protection class

 

ƒ

Sensor, controller: 

IP40 (only applies in the case of connected output connectors 

and/or installed protective caps)

Optical paths during operation are excluded from the protection class. Contamination of 
the paths causes impairment or failure of the function.
The IP40 protection class is a specification that is limited to protection from dust and wa-
ter. Oil, steam and emulsion effects are not included in this protection class and must be 
evaluated separately.

 - Temperature range

 

ƒ

Operation

 

• Sensor: 

5 ... +40 °C 

 

• Controller: 

-10 ... +60 °C

 1

 

ƒ

Storage

 

• Sensor: 

-10 ... +50 °C

 

• Controller: 

-40 ... +85 °C

 - Humidity:  

20 ... 80 % (non-condensing)

 - Ambient pressure:  Atmospheric pressure

1) Max. permissible operating temperature with 0.7 m/s air blow

4. 

Unpacking, Included in Delivery

 - 1 Sensor surfaceCONTROL 3D 25x0
 - 1 Controller SC2500
 - 1 Cable harness/5 m/standard for surfaceCONTROL
 - 1 Assembly Instructions
 - 1 Calibration protocol
 - 1 Table power pack for sensor
 - 1 Ethernet patch cable (Cat6A, gray, 5 m)
 - 1 DIN-rail mounting kit for controller
 - 1 Power supply cable (4-pin terminal strip to open ends)

  Carefully remove the components of the measuring system from the packaging and 

ensure that the goods are forwarded in such a way that no damage can occur.

  Check the delivery for completeness and shipping damage immediately after un-

packing.

  If there is damage or parts are missing, immediately contact the manufacturer or 

supplier.

Summary of Contents for surfaceCONTROL 3D SC2500

Page 1: ...the controller Do not touch the protective windows Remove any fingerprints immediately using pure alcohol and a clean cotton cloth without leaving any streaks Protect the cables against damage Failur...

Page 2: ...Controller 40 85 C Humidity 20 80 non condensing Ambient pressure Atmospheric pressure 1 Max permissible operating temperature with 0 7 m s air blow 4 Unpacking Included in Delivery 1 Sensor surfaceCO...

Page 3: ...uded in risk group 2 according to EN 62471 2008 Do not look into the lens Consciously close your eyes or im mediately turn away if the optical radiation enters the eye The warning sign below is attach...

Page 4: ...e connector panel on the rear side 1 2 3 4 1 Ethernet port Camera 1 2 Ethernet port Camera 2 3 Sensor control 4 Power supply Fig 2 Rear view of sensor with connectors Supply Voltage Power Pin Signal C...

Page 5: ...Pin assignment connector Ethernet port For the image data output of the cameras via Gigabit Ethernet the sensor has two Gigabit Ethernet interfaces The sensor supports only the transmission with 1 Gbi...

Page 6: ...roller front view with connectors Supply voltage Power The power supply connection is a 4 pin plug connector Pin Designation Comment 9 V 36 V DC nominal value 24 V max power consumption 112 W 0 V Fig...

Page 7: ...Dismantling Proceed as follows if you would like to detach the sensor from the tripod again Only for column stand option with boom Secure the boom of the tripod with the help of the clamping lever or...

Page 8: ...the delivery Connect the controller to the PC To do so use a common Ethernet cable of category CAT5e or higher Connect the sensor to the power supply Connect the controller to the power supply Turning...

Page 9: ...red for this 4 Connect the controller of the surfaceCONTROL 3D 25x0 measuring system to the PC via Ethernet Do not use hubs i If your network card supports the VLAN option this option must be disabled...

Page 10: ...the surface of the test object Alignment with Crosshair You will achieve the best results in the mid of the measurement area focal range of cam eras In the main view switch from the 3D View to the Im...

Page 11: ...ere created with the 3DInspect software from Micro Epsilon 14 Disclaimer All components of the device have been checked and tested for functionality in the factory However should any defects occur des...

Page 12: ...ess is defec tive If possible save the current sensor settings in a parameter set to reload them into the sensor after the repair Please send us the affected parts for repair or exchange If the cause...

Reviews: