Page 29
Mounting and Installation
scanCONTROL 29xx
5.2
Connections
5.2.1
General
1 2
1 Ethernet socket
2 Multifunction socket (Power supply, IO)
Fig. 16 Output sockets arrangement
Designation Sensor connector
Pin
Cable color
PCR3000-x
Notes
Connection view
+Ub
9
Red
+ 11 V - 30 V DC (rated
value 24 V); max. 500 mA
2
3
4
5
6
7
8
9
1
10
11
12
Screw connector,
solder pin side
GND
2
Blue
0 V
+Laser on/off 3
White
Optional
-Laser on/off 1
Brown
RS422
12
Red-blue
RS422
input or output
/RS422
11
Gray-pink
In1
6
Yellow
Switching input In1
GND-In1
4
Green
Ground connection In1
In2
5
Pink
Switching input In2
GND-In2
8
Gray
Ground connection In2
In3
10
Purple
Switching input In3
GND-In3
7
Black
Ground connection In3
Shield
Housing
Black
DC-insulated from GND
Fig. 17 Assignment of the multifunction socket on scanCONTROL 29xx
GND: Galvanically isolated from IN1, 2, 3, RS422, Laser on/off
Laser on/off: Input galvanically isolated from GND, IN1…3, RS422
IN1, IN2, IN3, RS422: Inputs galvanically isolated from GND and Laser on/off