Installation and Mounting
scanCONTROL 30xx
The multifunction socket can be used with either of the following configurations:
Configuration
Direction
Standard setting for
terminating resistor R
T
0
Half-duplex, serial communication with 115200 Baud input/output
On
1
Half-duplex, serial communication with 57600 Baud
input/output
2
Half-duplex, serial communication with 38400 Baud
input/output
3
Half-duplex, serial communication with 19200 Baud
input/output
4
Half-duplex, serial communication with 9600 Baud
input/output
5
External trigger input
input
On
6
External trigger output
output
Off
7
CMM trigger output
output
Off
Synchronizing several sensors with each other:
Connect the output RS422+ (Pin 12) of sensor 1 with the input RS422+ (Pin 12) of sensor 2.
Connect the output RS422- (Pin 11) of sensor 1 with the input RS422- (Pin 11) of sensor 2.
Also connect both the GND-RS422 (Pin 10) of the sensors to each other.
Software settings:
Setting
Sensor 1
Sensor 2
1
Other sensors
RS422 mode
External trigger output
External trigger input
External trigger input
RS422 termination
Off
On
Off
Fig. 13 External synchronization settings
The sensor 1 then synchronizes the sensor 2 and further sensors as master.
1) The terminating resistor is activated (On) at the sensor that is physically furthest away from sensor 1 (Master).