Page 78
Appendix | Software
induSENSOR DTD / MSC7xxx
Analog output
Output range
Automatic / 0.0 V .. 10.0 V / 2.0 V .. 10.0 V / 0.0
V .. 5.0 V / 0.5 V .. 4.5 V / 4.0 mA .. 20.0 mA /
0.0 mA .. 20.0 mA / 0.0 mA .. 10.0 mA
Frequency
response
20 Hz / 50 Hz / 100 Hz / 200 Hz / 300 Hz
-
If
automatic
is selected under
Analog output
>
Output range
, the output load is analyzed automati-
cally after the electronics are switched on.
Depending on the result, 4 ... 20 mA or 2 ... 10 V is output.
Alternatively you may set the output range manually via the drop down menu
.
Frequency response:
In order to achieve an optimal resolution, it is recommended to reduce the frequency response as much as
possible.
i
Please note that a reduced frequency response also involves a reduced measurement dynamics.
Fields with gray
background re-
quire a selection.
Fields with dark
border require
entry of a value.