![MICRO-EPSILON ILR1020-6 Operating Instructions Manual Download Page 16](http://html1.mh-extra.com/html/micro-epsilon/ilr1020-6/ilr1020-6_operating-instructions-manual_1785264016.webp)
Page 16
Installation
optoNCDT ILR 102x/110x/115x
Reflector
Reflector
Reflector
Top
Top
Top
Fig. 10 Reflector orientation
It is possible to align the sensor over a max. distance of approximately 50 m using the integrated red light
target laser.
i
For larger distances, use the aligning aid (ILR-AA1) listed in the accessories, see Chap.
A 1
.
This aligning aid, makes it possible to check the position of the red light target laser spot on the reflector at
very long ranges (>100 m). When aligning first check that the light spot is in the center of the reflector at a
very short distance (e. g. < 1 m). The reflector is then moved to its final position with the longest range and
the position of the light spot is checked again and adjusted if necessary. Finally, check the position of the
light spot again close-up. The light spot must always be in the center of the reflector whatever the position.
The fine adjustment set (LR-FA1) available as an accessory can be used for finer adjustment, see Chap.
A 1
.