Page 14
Functional Principle, Technical Data
optoNCDT 1402
Technical Data
3.3
Model
ILD 1402-5
1402-10
1402-20
1402-50 1402-100
1402-200
1402-250VT
1402-600
Measurement range
mm
5
10
20
50
100
200
250
600
Start of range
mm
20
20
30
45
50
60
100
200
Midrange
mm
22.5
25
40
70
100
160
225
500
End of range
mm
25
30
50
95
150
260
350
800
Linearity
µm
5 ... 9
5 ... 18
7 ... 36
12 ... 90
20 ...180
40 ... 360
50 ... 1200
120 ... 3000
0.18 % FSO
0.5 % FSO
Resolution
static, µm
0.6
1
2
5
10
20
50
120
0.01 % FSO
1
0.02 % FSO
1
dynamic, µm
1.5 kHz
1 ... 3
2 ... 5
5 ... 10
6 ... 25
12 ... 50
13 ... 100
32 ... 300
80 ... 600
0.02 ... 0.05 % FSO
0.02 ... 0.12 % FSO
Measurement rate, programmable:
1.5 kHz; 1 kHz; 750 Hz; 375 Hz; 50 Hz
Light source
Semiconductor laser 1 mW, 670 nm (red)
Laser class
Class 2 (II) acc. to DIN EN 60825-1: 2007
Spot diameter
SMR, µm
110
110
210
1100
1400
2300
5000
2,6 x 5 mm
MR, µm
380
650
530
110
130
2200
5000
2,6 x 5 mm
EMR, µm
650
1200
830
1100
1400
2100
5000
2,6 x 5 mm
Protection class
IP 67
Vibration
15 g / 10 Hz ... 1 kHz
20 g / 10 Hz ... 1 kHz
Shock
15 g / 6 ms (IEC 68-2-29)
Weight, without cable
approx. 83 g
approx. 130 g
Temperature stability
0.03 % FSO/°C
0.08 % FSO/°C
Operation temperature
0 ... 50 °C
Storage temperature
-20 °C ... 70 °C
Measurement value
output
analog
4 ... 20 mA (1 ... 5 V with cable PC 1402-3/U) or
digital
RS422