Seite 19
Installation and Assembly
capaNCDT 61xx/IP
CSE05/M8
CSE1,25/M12
CSE2/M16
CSE3/M24
14.0
17.0
(.67)
+0.1 -0.2
13.
4
WS6
18.5
22.
0
(.87)
17.
6
18.5
22.
0
(.87)
17.
6
25.5
30.
0
(1.18)
24.
6
3.0
(.12)
ø5.7
ø6.0
(.24 dia.)
ø9.7
ø10
ø10.4
(.41 dia.)
M8x0.5
M12x1
M16x1
M24x1.5
4.0
(.16)
4.0
(.16)
5.0
(.20)
ø13.7
ø14.0
ø14.4
(.57 dia.)
ø19.2
ø20.0
ø20.6
(.81 dia.)
WS10
6.0
(.24)
10.0
(.39)
WS14
WS18
Fig. 10 Cylindrical sensors with thread and male connector,
dimensions in mm (inches)
Connector side
Sensor
Torque
Preferred mounting:
Screw the sensor into the
sensor holder.
Turn the mounting nut on.
Do not exceed torques.
Dimensions in mm (inches),
dimensional drawings of other sensors
are available on request.
CSE05/M8
2.5 Nm max.
CSE1,5/M12
10 Nm max.
CSE2/M16
20 Nm max.
Active measuring surface sensor
CSE3/M24
70 Nm max.